IBM Support

PM24446: GENERAL FIXES AT GA DELIVERY TIME.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Various fixes in Object Analysis and VTAM.
    This PTF should be installed together with the GA tape.
    
    Additional symptom:
    If the length of the high level qualifier of the RTE exceeds
    25 characters the create runtime members job D2#3 will fail
    with a JCL error.
    
    e.g.
    Target dataset TKO2DATA,
    DBUTIL.DB2.OMEGAMON.V510.T101022.TKO2DATA has 41 characters,
    (KO2USR#P) has 10 characters,
    "//SYSUT1   DD", "DSN="  and  ",DISP=SHR" have 26 characters.
    The total length is greater than 71 characters.
    
    To get around the problem the customer has to manually edit the
    job to move the DISP=SHR to the next line.
    
    Additional Keywords
    SYSUT1 DD DSN DISP SHR
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - OMEGAMON Collector                         *
    *                 - Classic Interface                          *
    *                 - ICAT                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. Post GA abends in Object Analysis    *
    *                         with DB2 V10, NTH and VTAM.          *
    *                      2. If the length of the high level      *
    *                         qualifier of the RTE exceeds 25      *
    *                         characters the create runtime        *
    *                         members job D2#3 will fail with      *
    *                         a JCL error.                         *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    1. DB2 V10 GA can ABEND0C4 or ABEND0C1 after Object Analysis
       termination.
       Recovery loop if PGM CHK in panel ZUTIA.
    2. If the length of the high level qualifier of the RTE exceeds
       25 characters the create runtime members job D2#3 will fail
       with a JCL error.
    
    PROBLEM CONCLUSION:
    1. Object Analysis shutdown process corrected.
       Recovery loop fixed.
    2. Job D2#3 corrected.
    

Problem conclusion

  • 1. Object Analysis shutdown process corrected.
       Recovery loop fixed.
    2. Job D2#3 corrected.
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    PM24446

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2010-10-14

  • Closed date

    2010-11-08

  • Last modified date

    2017-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK61772

Modules/Macros

  •    HKDB510J KDB510J  KD2HTRC  KD2HTRCA KD2HTRCB
    KD2HTRCC KD261SJ4 KO2ACAFA KO2ACAFK KO2ACAF2 KO2ACAPA KO2ACAPK
    KO2ACAP2 KO2ACA0A KO2ACA0K KO2ACA02 KO2ACA1A KO2ACA1K KO2ACA12
    KO2ACA3A KO2ACA3K KO2ACA32 KO2ACA4A KO2ACA4K KO2ACA42 KO2ARSBA
    KO2ARSBK KO2ARSB2 KO2ARS0A KO2ARS0K KO2ARS02 KO2ARS1A KO2ARS1K
    KO2ARS12 KO2ARS2A KO2ARS2K KO2ARS22 KO2ARS3A KO2ARS3K KO2ARS32
    KO2ARS4A KO2ARS4K KO2ARS42 KO2ARS5K KO2ARS6A KO2ARS6K KO2ARS62
    KO2ARS7A KO2ARS7K KO2ARS72 KO2ARS8A KO2ARS8K KO2ARS82 KO2ASPFB
    KO2ASUAA KO2ASUAK KO2ASUA2 KO2ASUBA KO2ASUBK KO2ASUB2 KO2ASUDA
    KO2ASUDK KO2ASUD2 KO2ASU0A KO2ASU0K KO2ASU02 KO2ASU1A KO2ASU1K
    KO2ZPFLH KO2ZPRM  KO2ZRCM  KO2ZREQ  KO2ZRIO  KO2ZRMDA KO2ZRMDK
    KO2ZRMD2 KO2ZROU  KO2ZRTM  KO2ZSIP  KO2ZSND  KO2ZSRB  KO2ZSSI
    KO2ZSTO  KO2ZSTS  KO2ZSUB  KO2ZSVC  KO2ZSVS  KO2ZSVU  KO2ZTMR
    KO2ZTOP  KO2ZTRM  KO2ZUCM  KO2ZUTL  KO2ZVAT  KO2ZVCS  KO2ZVLS
    KO2ZWTO  KO2ZXCB  KO2ZXCF  KO2ZXCM  KO2ZXCQ  KO2ZXCT  KO2ZXDQ
    KO2ZXGP  KO2ZXIO  KO2ZXNO  KO2ZXPC  KO2ZXQR  KO2ZXRB  KO2ZXRD
    KO2ZXRE  KO2ZXRM  KO2ZXRR  KO2ZXSN  KO2ZXST  KO2ZZIP  KO2ZZPC
    KO2ZZPS  KO2ZZRM
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R510 PSY UK61772

       UP10/11/12 P F011 Ž

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
04 February 2017