A fix is available
APAR status
Closed as program error.
Error description
1. An exception profile containing conditions involving Real Time Statistics does not trigger any objects even though they meet the criteria. An example is when DB2 Automation Tool contains an exception profile condition such as: REALTIME ICOPY REAL TIME STAT REORG_OR_LOAD DAYS_SINCE_LAST EQ This does not generate a Image Copy (the job is returning RC00000006) if a REORG or LOAD has been run after the latest Image Copy. 2. HAAB381W message may be unnecessarily generated when building IMAGE COPY JCL. This message is unnecessary as message HAAB374W is has already informed the user that RECOVERY EXPERT IC will not be processed. 3. Message HAAB381W contains the word "RECOVER" which should be "RECOVERY" 4. Entering a floating point number with a large exponent ending in 9 on the HAA$EPRU panel causes the exponent to be truncated. For example, when a number such as 1.3e+39, 3e+49, 1.1e+59, etc. Is entered on the HAA$EPRU panel and the Exception Profile is saved, the exponent value gets truncated to 4, 5, 6, etc. instead of 40, 50, 60 when the Exception Profile is later Viewed or Updated. 5. Currently on panel HAA$JOPT, the first line of the panel is displayed as follows: HAA$JOPT ===> HAA$JOPT will be moved up one line and the keyword "OPTION" will be added so it will now be displayed as follows: HAA$JOPT Option ===>
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Automation Tool. * **************************************************************** * PROBLEM DESCRIPTION: 1. An exception profile containing * * conditions involving Real Time * * Statistics does not trigger any objects * * even though they meet the criteria. * * An example is when DB2 Automation * * Tool contains an exception profile * * condition such as: * * * * REALTIME ICOPY REAL TIME STAT * * REORG_OR_LOAD * * DAYS_SINCE_LAST EQ * * * * This does not generate a Image Copy * * (the job is returning RC00000006) * * if a REORG or LOAD has been run * * after the latest Image Copy. * * 2. HAAB381W message may be * * unnecessarily generated when building * * IMAGE COPY JCL. This message is * * unnecessary as message HAAB374W has * * already informed the user that RECOVERY * * EXPERT IC will not be processed. * * 3. Message HAAB381W contains the word * * "RECOVER" which should be "RECOVERY". * * 4. Entering a floating point number * * with a large exponent ending in 9 on * * the HAA$EPRU panel causes the exponent * * to be truncated. For example, when a * * number such as 1.3e+39, 3e+49, 1.1e+59, * * etc. Is entered on the HAA$EPRU panel * * and the Exception Profile is saved, the * * exponent value gets truncated to 4, 5, * * 6, etc. instead of 40, 50, 60 when the * * Exception Profile is later Viewed or * * Updated. * * 5. Currently on panel HAA$JOPT, the * * first line of the panel is displayed * * as follows: * * HAA$JOPT ===> * * HAA$JOPT will be moved up one line * * and the keyword "OPTION" will be * * added so it will now be displayed as * * follows: * * HAA$JOPT * * Option ===> * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PM17549
Reported component name
DB2 AUTOMATION
Reported component ID
5697G6300
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-06-29
Closed date
2010-08-03
Last modified date
2010-09-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
HAA52
Fix information
Fixed component name
DB2 AUTOMATION
Fixed component ID
5697G6300
Applicable component levels
R310 PSY UK59386
UP10/08/05 P F008
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUWB","label":"IBM Db2 Automation Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
12 February 2021