IBM Support

PM16708: VARIOUS ENHANCEMENTS AND FIXES

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • Enhancements:
    - PROVIDE COMPATIBILITY WITH IMS TOOLS GENERIC EXITS.
    - PROVIDE SUPPORT FOR THE TRANSTAT= AND EXPRTIME= KEYWORD OF
      THE TRANSACT MACRO IN IMS V10.
    Corrections:
    - FAST PATH PSBS CAN SOMETIMES SHOW AS PGMTYPE=BATCH INSTEAD
      OF PGMTYPE=TP.
    - PROPERLY SET SYSGEN DEFINITION OF RESIDENT BITS IN PDIR AND
      DDIR (PDIRRESY and DDIRRESY) FOR IMS V10 AND V11.
    - USER SECURITY (HP SYSGEN OPTION 0.4) DOES NOT VALIDATE
      SECURITY VIA CLASS FACILITY PROFILE IOH.SETUP.
    - CSA MAP BY SUBPOOL AND KEY ABENDS WITH ABEND0C1 WHEN USER KEY
      CSA IS ALLOCATED.
    - PREVENT CREATION OF IMS GROUPS THAT START WITH IOH, AND
      PREVENT DISPLAY OF ANY GROUPS OR OTHER MEMBERS OF THE IOHOPT
      DATA SET THAT START WITH IOH.
    - HELP SCREEN IOHZ0040 CAN NOT BE DISPLAYED ON A
      24 LINE TERMINAL.
    KEYWORDS: IMSV11TGT/K  IMSV10TGT/K
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IMS HIGH PERFORMANCE SYSGEN USERS.           *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. Provide compatibility with IMS Tools *
    *                      Generic Exits.                          *
    *                      2. Provide support for the TRANSTAT=    *
    *                      and EXPRTIME= keywords of THE TRANSACT  *
    *                      MACRO in IMS V10.                       *
    *                      3. Correct several other items.         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    This APAR is making the following enhancements:
    1. Provide compatibility with IMS Tools Generic Exits.
    2. Provide support for the TRANSTAT= and EXPRTIME= keywords
    of the TRANSACT MACRO in IMS V10.
    This APAR is also making the following corrections:
    1. Fast Path PSBS can sometimes show as PGMTYPE=BATCH instead
    of PGMTYPE=TP.
    2. Properly set SYSGEN definition of resident bits in PDIR
    and DDIR (PDIRRESY/DDIRRESY) for IMS V10 and V11.
    3. User security (HP SYSGEN OPTION 0.4) does not validate
    security via Class Facility Profile IOH.SETUP.
    4. CSA Map by SUBPOOL and KEY abends with ABEND0C1 when
    user key CSA is allocated.
    5. Prevent creation of IMS groups that start with IOH and
    prevent display of any groups or other members of the IOHOPT
    data set that start with IOH.
    6. HELP screen IOHZ0040 can not be displayed on a 24 line
    terminal.
    

Problem conclusion

Temporary fix

Comments

  • The following changes have been made for the above
    enhancements:
    1. Provide support for IMS Tools Generic Exits in IMS
    HP Sysgen Tools.
    2. Add support for the TRANSTAT and EXPRTIME keywords of the
    TRANSACT MACRO in IMS V10.
    The following changes have been made for the above problems:
    1. Properly set Fast Path PSB TYPE (BATCH or TP).
    2. Update HP Sysgen to properly set PDIRRESY and DDIRESY
    in IMS V10/V11.
    3. Add RACROUTE check for access to IOH.SETUP in Class
    Facility when accessing userid setup.
    4. Fix error when processing user key CSA in CA MAP Utility.
    5. Restrict IMS Group Names from starting with IOH.
    6. Correct Panel IOHZ0040 to be 24 lines.
    

APAR Information

  • APAR number

    PM16708

  • Reported component name

    IMS HP SYSGEN T

  • Reported component ID

    5655F4300

  • Reported release

    220

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2010-06-16

  • Closed date

    2010-06-22

  • Last modified date

    2010-08-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK58153

Modules/Macros

  • H24Q220J IOHA14   IOHCLST2 IOHCSA1  IOHDDIR0
    IOHDDIR1 IOHDDIR7 IOHDDIR8 IOHDDIR9 IOHEDEX  IOHEDEX0 IOHEDEX1
    IOHFMAC  IOHICL60 IOHICL61 IOHICL67 IOHICL68 IOHICL69 IOHJCLN0
    IOHJCLN1 IOHJCLN7 IOHJCLN8 IOHJCLN9 IOHMBLK0 IOHMBLK1 IOHMBLK7
    IOHMBLK8 IOHMBLK9 IOHMD071 IOHMD081 IOHMD091 IOHMD101 IOHMD111
    IOHMWX   IOHPDIR0 IOHPDIR1 IOHPDIR7 IOHPDIR8 IOHPDIR9 IOHPPUE0
    IOHSDIR0 IOHSDIR1 IOHSDIR7 IOHSDIR8 IOHSDIR9 IOHTIME  IOHXCSA
    IOHXGRP  IOHXIMS  IOHXINIT IOHXUSR  IOHYT031 IOHYT032 IOHZCHK0
    IOHZCHK1 IOHZCHK7 IOHZCHK8 IOHZCHK9 IOHZCTL0 IOHZCTL1 IOHZCTL7
    IOHZCTL8 IOHZCTL9 IOHZCTU0 IOHZCTU1 IOHZCTU7 IOHZCTU8 IOHZCTU9
    IOHZE010 IOHZGET0 IOHZGET1 IOHZGET7 IOHZGET8 IOHZGET9 IOHZINST
    IOHZMODA IOHZMODB IOHZRACF IOHZRCB0 IOHZRCB1 IOHZRCB7 IOHZRCB8
    IOHZRCB9 IOHZUPD0 IOHZUPD1 IOHZUPD7 IOHZUPD8 IOHZUPD9 IOHZ0040
    

Publications Referenced
SC18947406    

Fix information

  • Fixed component name

    IMS HP SYSGEN T

  • Fixed component ID

    5655F4300

Applicable component levels

  • R220 PSY UK58153

       UP10/06/23 P F006

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89J","label":"IMS HP System Generation Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0"}]

Document Information

Modified date:
22 October 2020