A fix is available
APAR status
Closed as program error.
Error description
When Index Builder builds index while taking physical image copy under DRF, the timestamp of NOTIFY.REORG is later than the timestamp of NOTIFY.IC. This is a data-integrity issue.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS Index Builder for z/OS, * * Version 3 Release 1 (FMID=H22O310) * **************************************************************** * PROBLEM DESCRIPTION: This APAR fixes the following problems: * * 1. Under IMS Database Recovery Facility * * (DRF), the RUN time of a REORG record * * in the RECON data sets for an index * * is later than the RUN time of a IMAGE * * record. The RUN time of the REORG * * record should be earlier. * * * * 2. ABENDS378-14 during the DBRC signoff * * process. The reason is considered as * * invoking DBRC API in another task * * running concurrently with IMS batch * * control region. * **************************************************************** * RECOMMENDATION: * **************************************************************** This APAR fixes the problems listed in the Problem Description field.
Problem conclusion
This APAR fixes the problems listed in the Problem Description field. For the problem 1, the RUNTIME option of the DBRC NOTIFY.REORG command is specified when Index Builder is started in a DRF job. For the problem 2, invocation of DBRC API is moved.
Temporary fix
Comments
APAR Information
APAR number
PM15887
Reported component name
IMS INDEX BUILD
Reported component ID
5655E2400
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2010-06-03
Closed date
2010-06-24
Last modified date
2010-07-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK58260
Modules/Macros
IBCD IIUBINIT IIUPDBRC IIUSTART SIBCD
Fix information
Fixed component name
IMS INDEX BUILD
Fixed component ID
5655E2400
Applicable component levels
R310 PSY UK58260
UP10/06/28 P F006
Fix is available