APAR status
Closed as program error.
Error description
When running Rational Developer for System z V7.5.1.1 V7.6.0.1 passwords greater than eight characters are not validated. The problem is that a password has to be unique. '12345678' is a different password than '123456789' and should be treated that way. If the one enters '123456789', it would be expected that an error password message should be issued, even if the password is limited to 8 characters and '12345678' is the correct one. This would cause a security problem for the client.
Local fix
Problem summary
The RseDaemon truncated the password up to 8 byte-length and then authenticated the userid and password.
Problem conclusion
Now the RseDaemon authenticates the userid and password just as the client enters them. The problem listed in this APAR has been resolved with IBM Rational Developer for System z V7.6.1 Refresh Pack which is available from the Recommended Fixes support download page: http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
Temporary fix
Comments
APAR Information
APAR number
PM13124
Reported component name
RATL DEV FOR SY
Reported component ID
5724T0700
Reported release
751
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-04-26
Closed date
2010-05-22
Last modified date
2010-05-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL DEV FOR SY
Fixed component ID
5724T0700
Applicable component levels
R761 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSJK49","label":"IBM Developer for z Systems"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]