A fix is available
APAR status
Closed as program error.
Error description
Dataset name checking is not always consistent for all fields. If a name is incorrect or an N is specified, sometimes you get incorrect JCL and sometimes you get dataset not found on the panel.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: DATABASE CONTROL SUITE USERS WITH REL 3.2 * **************************************************************** * PROBLEM DESCRIPTION: INVALID DATA SET NAME 'N' DOES NOT * * GENERATE ERROR MESSAGE ON SET UP * * PANELS, BUT CAUSES ERRORS IN * * GENERATED JCL. * **************************************************************** * RECOMMENDATION: * **************************************************************** CONTROL SUITE PANELS FOR THE IMS ENVIRONMENT SET UP ALLOWED A USER TO PUT 'N' IN THE DYNLIB DATA SET FIELD. NO 'INVALID DATA SET NAME' ERROR MESSAGE WAS ISSUED. THE ERROR WAS DISCOVERED IN GENERATED JCL THAT USED THE INVALID DYNLIB 'N' NAME. THE USER WAS TRYING TO DESIGNATE THAT DYNLIB WAS NOT USED IN HIS SET UP. DYNLIB, HOWEVER, IS REQUIRED FOR CONTROL SUITE.
Problem conclusion
THE DATA SET VALIDATION CODE FOR IMS ENVIRONMENT DATA SETS WAS CHANGED TO CHECK ALL NON-BLANK DATA SET FIELDS.
Temporary fix
Comments
APAR Information
APAR number
PM06318
Reported component name
IMS DB CNTL SUI
Reported component ID
5655F7600
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-01-28
Closed date
2010-04-30
Last modified date
2010-05-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK56635
Modules/Macros
IDLCS11 IDLC0001
Fix information
Fixed component name
IMS DB CNTL SUI
Fixed component ID
5655F7600
Applicable component levels
R320 PSY UK56635
UP10/05/01 P F004
Fix is available