A fix is available
APAR status
Closed as program error.
Error description
ABEND0C4-11 KO2AINIB+229E (at PK89128 level) on a D50A3000C389 (CLC) instruction with R3 plus its offset pointing beyond valid a valid 4k page. In this case R3 contained 00AC8FF6, at the end of a storage page. The following page was in a different subpool and marked invalid. Depending on what follows the page pointed to by R3, ABEND0C4-4 can also occur. R3 pointed to an area of storage containing 0029D7C1 D9D47E4D E3D9C1C3 C57ED5D6 | ..PARM=(TRACE=NO 6BE2E3C9 D4C5D97E F0F0F0F0 F3F0F0F0 | ,STIMER=00003000 6BE2D3E7 7ED9C5E4 E2C55D00 00000000 | ,SLX=REUSE)..... and this data can also be seen on the following messages just prior to the ABEND: KO2I0141I D5API COLLECTOR TRACE SET TO NO KO2I0141I D5API COLLECTOR STIMER SET TO 00003000 KO2I0141I D5API COLLECTOR SLX SET TO REUSE OMEGAMON II FOR DB2 DUMP: TASK=COMMCOLL,ID=V420 , MOD=KO2AINIB,OFFSET=0024DE, CI0970: OMEGAMON SUBTASK ABEND CODE=840C4000 CI0971: PROGRAM NAME=KO2AINIB Also seen are messages: KO2I0205U UNABLE TO LOCATE COMMON COLLECTOR REGISTRY ENTRY FOR OM SERVER KO2I0194I AGENT OMXED5 FAILED TO CONNECT TO - DB2 DDX2
Local fix
Change rhilev.RKD2PAR(OMPECCPC) to eliminate the PARM string. TRACE=NO and SLX=REUSE are the defaults, and STIMER will be set to 11 seconds instead of 30. STIMER is the data collection time-out value, it's the maximum amount of time the agend will wait for data from the D2 STC. Since the internal PE Server time-out value is 10 seconds, an STIMER value of 11 seconds is fine. Please comment out the existing line in OMPECCPC, so the new contents would be: *START COMMCOLL,PARM=(TRACE=NO,STIMER=00003000,SLX=REUSE) START COMMCOLL
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - The component that transfers DB2 * * monitoring data collected by the * * OMEGAMON collector to the TEMA * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C4 KO2AINIB+24DE at Common * * Collector start-up * **************************************************************** * RECOMMENDATION: Apply this PTF * * * **************************************************************** PROBLEM SUMMARY: During parsing of Common Collector start-up parameters, ABEND0C4 can occur if the parameters happen to be allocated at the end of a page. PROBLEM CONCLUSION: Ensure parameter parsing doesn't address unallocated storage.
Problem conclusion
Ensure parameter parsing doesn't address unallocated storage. KEYWORDS : ABEND0C4 KO2AINIB+24DE COMMON COLLECTOR START-UP PARAMETERS
Temporary fix
Comments
APAR Information
APAR number
PM05923
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-01-25
Closed date
2010-02-18
Last modified date
2010-05-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK54456 UK54457
Modules/Macros
KO2AINIB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
28 May 2010