APAR status
Closed as program error.
Error description
This defect is raised from ER: RATLC01487901. Client is using RBD V7.1.0.4 and WAS WAS ND V6.1.0.19 on AIX, th ey found when their WAS http persistence session is turn on, the ir EGL/Java application will get rollback exception automaticlly , although they have committed connection explicitly in EGL appl ication. development team has confirmed this is a defect in product in ER : RATLC01487901, and provided a testfix for client, which was te sted and accepted by client, so I raised this defect.
Local fix
Problem summary
When WAS Distribited environment settings are set to "Database", the database work used by JSF Handlers may be rolled back. All changes will be lost.
Problem conclusion
When WAS Distribited environment settings are set to "Database", set the system property com.ibm.egl.noRollbackOnSerialize to true. To set the system property in WAS 6.1, start the administrative console. Click Servers ? Application servers ? [server_name] ? Java and process management ? Process definition ? Java virtual machine ? Custom properties ? New. Name the new property com.ibm.egl.noRollbackOnSerialize, and enter true for the value. The change will take effect after WAS is restarted.
Temporary fix
Comments
APAR Information
APAR number
PK99241
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-10-22
Closed date
2010-02-11
Last modified date
2010-02-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R710 PSN
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: