Error description

  • ABEND0C4-11 FPECHGVR+F12
    
    ICE185A 0 AN S0C4  ABEND WAS ISSUED BY DFSORT, ANOTHER PROGRAM
    OR AN EXIT (PHASE S 1)
    A system abend 0C4 reason code X'10' occurred in module DB2PM
    CSECT FPECHGVR at offset X'F12'.
    

Local fix

  • This problems comes up only when having big (e.g 60000 tracks)
    trace dataset.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   Batch Reporting                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: Abend occurs because of wrong           *
    *                      GTF record - product section offset     *
    *                      is negative                             *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    *                                                              *
    ****************************************************************
    PROBLEM SUMMARY:
    Abend occurs because of wrong GTF record - product section
    offset is negative
    PROBLEM CONCLUSION:
    Add product section offset checking to exclude wrong records
    from further processing.
    

Problem conclusion

  • Add product section offset checking to exclude wrong records
    from further processing.
    
    KEYWORDS : GTF PRODUCT SECTION OFFSET NEGATIVE
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK96651

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-09-18

  • Closed date

    2009-10-22

  • Last modified date

    2009-11-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK51244 UK51245

Modules/Macros

  • FPECHGVR
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R410 PSY UK51244

       UP09/10/23 P F910

  • R420 PSY UK51245

       UP09/10/23 P F910

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]