IBM Support

PK95679: ABENDS878 RC08 IN KO2EOJAB WITH OBJECT ANALYSIS ( OA ) OPTION CAUSING POSSIBLE CSA OR ECSA LEAK IF OA INITIALIZATION FAILS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Dump Title: COMPON=VSM,COMPID=SC1CH,ISSUER=IGVVSERR,OUT_OF_CSA
    Also seen at this time:
     IEA705I ERROR DURING GETMAIN SYS CODE = 878-08 OMPH1 OMPH1 00
     IEA705I 00F6D580 00AC1E88 00AC1E88 00F17203 0000E888
     IEA794I SVC DUMP HAS CAPTURED: 576
     DUMPID=001 REQUESTED BY JOB (OMPH1   )
     DUMP TITLE=COMPON=VSM,COMPID=SC1CH,ISSUER=IGVVSERR,OUT_OF_CSA
    The Omegamon JOBLOG showed the following group of messages
    repeated many times:
     KO2E3070I  DAP9 OBJECT ANALYSIS INITIALIZATION IN PROGRESS
     KO2E3050I  DAP9 OBJECT ANALYSIS PHASE1 INITIALIZATION COMPLETE
     KO2E3066S  DAP9 OBJECT ANALYSIS INITIALIZATION FAILED, REASON
                     CODE=2001
     KO2E3062I  DAP9 OBJECT ANALYSIS PHASE1 TERMINATION COMPLETE
     KO2E3063I  DAP9 OBJECT ANALYSIS PHASE2 TERMINATION COMPLETE
     KO2E3064I  DAP9 OBJECT ANALYSIS TERMINATION SUCCESSFUL
     KO2E3070I  DAP9 OBJECT ANALYSIS INITIALIZATION IN PROGRESS
    .
    Upon restart of DB2, Object Analysis will attempt to reconnect
    to the DB2 subsystem and cannot get enough storage, exhausting
    CSA and ECSA and resulting in the ABEND878-08.
    
    CSA and ECSA contained hundreds of copies of KO2EIX1A as seen
    These unnecessary copies of KO2EIX1A are similar to APAR PK74463
    which can be seen is already on the system.  The 'Ret Addr'
    points to code with an eyecatcher of 'O2EOJS' (KO2EOJSA).
    eyecatcher: O2EIX1
    

Local fix

  • Run Omegamon without object analysis.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   Classic Interface                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: CSA Storage not freed if Object         *
    *                      Analysis initialization fails.          *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    *                                                              *
    ****************************************************************
    PROBLEM SUMMARY:
    If Object Analysis Initialization fails during 2nd Phase of
    initialization, CSA storage allocated in First Phase is not
    released.
    
    PROBLEM CONCLUSION:
    Release all storage on initialization failure.
    

Problem conclusion

  • Release all storage on initialization failure.
    
    KEYWORDS : OBJECT ANALYSIS INITIALIZATION CSA RELEASE
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    PK95679

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-09-08

  • Closed date

    2009-10-28

  • Last modified date

    2011-01-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK51478 UK51479 PM26677

Modules/Macros

  • KO2EOJSA KO2EOJSS KO2EOJS2
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R410 PSY UK51478

       UP09/11/04 P F911

  • R420 PSY UK51479

       UP09/11/04 P F911

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
13 January 2011