Error description
Dump Title: COMPON=VSM,COMPID=SC1CH,ISSUER=IGVVSERR,OUT_OF_CSA Also seen at this time: IEA705I ERROR DURING GETMAIN SYS CODE = 878-08 OMPH1 OMPH1 00 IEA705I 00F6D580 00AC1E88 00AC1E88 00F17203 0000E888 IEA794I SVC DUMP HAS CAPTURED: 576 DUMPID=001 REQUESTED BY JOB (OMPH1 ) DUMP TITLE=COMPON=VSM,COMPID=SC1CH,ISSUER=IGVVSERR,OUT_OF_CSA The Omegamon JOBLOG showed the following group of messages repeated many times: KO2E3070I DAP9 OBJECT ANALYSIS INITIALIZATION IN PROGRESS KO2E3050I DAP9 OBJECT ANALYSIS PHASE1 INITIALIZATION COMPLETE KO2E3066S DAP9 OBJECT ANALYSIS INITIALIZATION FAILED, REASON CODE=2001 KO2E3062I DAP9 OBJECT ANALYSIS PHASE1 TERMINATION COMPLETE KO2E3063I DAP9 OBJECT ANALYSIS PHASE2 TERMINATION COMPLETE KO2E3064I DAP9 OBJECT ANALYSIS TERMINATION SUCCESSFUL KO2E3070I DAP9 OBJECT ANALYSIS INITIALIZATION IN PROGRESS . Upon restart of DB2, Object Analysis will attempt to reconnect to the DB2 subsystem and cannot get enough storage, exhausting CSA and ECSA and resulting in the ABEND878-08. CSA and ECSA contained hundreds of copies of KO2EIX1A as seen These unnecessary copies of KO2EIX1A are similar to APAR PK74463 which can be seen is already on the system. The 'Ret Addr' points to code with an eyecatcher of 'O2EOJS' (KO2EOJSA). eyecatcher: O2EIX1
Local fix
Run Omegamon without object analysis.
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - Classic Interface * **************************************************************** * PROBLEM DESCRIPTION: CSA Storage not freed if Object * * Analysis initialization fails. * **************************************************************** * RECOMMENDATION: Apply this PTF * * * **************************************************************** PROBLEM SUMMARY: If Object Analysis Initialization fails during 2nd Phase of initialization, CSA storage allocated in First Phase is not released. PROBLEM CONCLUSION: Release all storage on initialization failure.
Problem conclusion
Release all storage on initialization failure. KEYWORDS : OBJECT ANALYSIS INITIALIZATION CSA RELEASE
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PK95679
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt
Submitted date
2009-09-08
Closed date
2009-10-28
Last modified date
2011-01-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK51478 UK51479 PM26677
Modules/Macros
KO2EOJSA KO2EOJSS KO2EOJS2
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
13 January 2011