A fix is available
APAR status
Closed as program error.
Error description
For GCL to issue commands to an IMS subsystem it has to locate the SSCD for the active IMS. When searching the SSCVT fo an IMS subsystem, if there is a subsystem defined that ends with the characters 'DC' prio to the IMS subsystem GCL is looking for, the GCLxxx21E ERROR ISSUNG IMS COMMAND, RC=0008 RSN=00001029 will occur.
Local fix
Deactivate the subsystem with the 'DC' suffix or manually STOP/START the IMS subsystem.
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Cloning Tool V1.1 who receive * * error GCL31521E while issuing IMS command. * **************************************************************** * PROBLEM DESCRIPTION: GCL31521E error issuing IMS command, * * RC=0008 RSN=00001029 * **************************************************************** * RECOMMENDATION: * **************************************************************** For GCL to issue commands to an IMS subsystem it has to locate the SSCD for the active IMS. When searching the SSCVT for an IMS subsystem, if there is a subsystem defined that ends with the characters 'DC' prior to the IMS subsystem GCL is looking for, the GCLxxx21E ERROR ISSUING IMS COMMAND, RC=0008 RSN=00001029 will occur.
Problem conclusion
Code has been modified to correct the above problem.
Temporary fix
Comments
APAR Information
APAR number
PK95410
Reported component name
IMS CLONING TOO
Reported component ID
5655U9100
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2009-09-03
Closed date
2009-09-29
Last modified date
2009-11-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK50622
Modules/Macros
GCLICMD GCL00310 GCL00330 GCL00335 GCL00342 GCL00343
Fix information
Fixed component name
IMS CLONING TOO
Fixed component ID
5655U9100
Applicable component levels
R110 PSY UK50622