A fix is available
APAR status
Closed as program error.
Error description
If the CEX journal manager attempts to submit an archive job to JES via the internal reader while JES is not available, the internal reader process will hang and prevent CEX from journaling any event records until JES has been restarted. This is likely to result in the IMS Connect region entering a wait state because all of the event recording buffers are full.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Functional Support Library V2.2 * **************************************************************** * PROBLEM DESCRIPTION: CEX wait if archive job submitted * * while JES2 is down. * **************************************************************** * RECOMMENDATION: * **************************************************************** 1. If the CEX journal manager attempts to submit an archive job to JES via the internal reader while JES is not available, the internal reader process will hang and prevent CEX from journaling event records until JES has been restarted. This is likely to result in the IMS Connect region entering a wait state because all of the event recording buffers are full. 2. Utility FUNMIGUT can fail if the trap for Dirty Getmain is active
Problem conclusion
1. This APAR changes the CEX Journal Manager component to submit the archive job using an asynchronous process that does not cause the journal manager task to wait for the archive jobstep submission. 2. Corrected FUNMIGUT to properly clear storage obtain
Temporary fix
Comments
APAR Information
APAR number
PK93877
Reported component name
FUNC SUPP LIBRA
Reported component ID
5655K4801
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2009-08-13
Closed date
2009-11-19
Last modified date
2009-12-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK52133
Modules/Macros
FUNJRN01 FUNJRN03 FUNMIGUT
Fix information
Fixed component name
FUNC SUPP LIBRA
Fixed component ID
5655K4801
Applicable component levels
R220 PSY UK52133
UP09/11/24 P F911