IBM Support

PK93373: AUTOSAR WRONG ACCESS METHOD FOR 1 PORT AND MULTIPLA DATA

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • defect 225989
    Wrong data access method is used if you have one port and inside
    several data.
    Inside a port you can have several data, each data can have a
    specific 'Data Exchange Behavior'.
    
    For example you have a data-flow DF1 (used as port) which
    consists of the data-items D1 and D2 with different Design
    Attributes, 'Data Access' for D1 and 'Data Point' for D2.
    The generated code only uses 'Data Point' as access methods.
    

Local fix

  • - use multiple ports for each data-item
    - do not use data-flows as port
    

Problem summary

  • Wrong access method for 1 port and multiple data
    

Problem conclusion

  • The workflow is to edit port/interface related attributes
    and IB attributes within SAG, Data-types and RunnableEntity
    related attributes with STM.
    The resolution of "Data Exchange Method" and "Data Exchange
    Behavior" is per port. In order to define data-elements with
    different attributes, use different ports (Flow-Lines).
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK93373

  • Reported component name

    TLOGIC STATEMAT

  • Reported component ID

    5724V76SM

  • Reported release

    460

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-08-07

  • Closed date

    2010-04-26

  • Last modified date

    2010-04-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSYQ4J","label":"Rational Statemate"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.6","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
26 April 2010