A fix is available
APAR status
Closed as program error.
Error description
HISTORICAL COLLECTOR ABNORMAL TERMINATION AFTER RECOVERY ATTEMPTS EXCEEDED. KO2O1360E NEAR-TERM HISTORY DATA COLLECTOR - DATA CAPTURE FAILED WITH RC=10, RSC=0318, ARSC=0000 DB2=QSSB (CHKRETCD) IEA794I SVC DUMP HAS CAPTURED: DUMPID=001 REQUESTED BY JOB (CANSO2 ) DUMP TITLE=OMEGAMON II FOR DB2: COMPID=5655OPE00, JOB=CANSO2, LMOD=KO2SSRVB#L, CSECT=O2HPRC , OFFSET=00CF86 KO2O1360E NEAR-TERM HISTORY DATA COLLECTOR - DATA CAPTURE FAILED WITH RC=10, RSC=0318, ARSC=0000 DB2=QSSB (CHKRETCD) Diagnostic dump was taken during H2 abnormal termination after recovery attempts exceeded. Historical collector ABENDed with Dump Title: OMEGAMON II FOR DB2: COMPID=5655OPE00, JOB=CANSO2 , LMOD=KO2SSRVB#L, CSECT=O2HSVP , OFFSET=0006D4 documenting an intentional ABEND0C3 KO2HSVPB+6D0 (at PK84778 level) and putting out message KO2O1422E NEAR-TERM HISTORY DATA COLL. - WORKLOAD SQLWRITE HAD PROGRAM CHECK MORE THAN 10 TIMES. TERMINATING (SERVPROE) The message documents the real problem, 10 program checks ABEND0C4-4 KO2DCS2B+11C8 (at PK73025 level) on a 0E62 (MVCL) instruction with R6 = 00000000.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - The component that transfers DB2 * * monitoring data collected by the * * OMEGAMON collector to the TEMA * **************************************************************** * PROBLEM DESCRIPTION: Historical collector abnormal * * termination with message KO2O1360E or * * KO2O1422E. Abend0C4 in KO2DCS2B offset * * 0011CA. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: Zero address has caused ABEND0C4. PROBLEM CONCLUSION: Change code to prevent the abend.
Problem conclusion
Change code to prevent the abend. KEYWORDS : ABEND0C4 KO2DCS2B OFFSET 0011CA
Temporary fix
Comments
APAR Information
APAR number
PK91608
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-07-16
Closed date
2009-09-03
Last modified date
2010-05-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK49819 UK49820
Modules/Macros
KO2DCS2B
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
18 May 2010