IBM Support

PK87423: ABEND0C4 WHEN RELOADING A (P)HDAM

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABEND0C4 in HPSRHRPT when reloading a (P)HDAM and the average
    length of data in the overflow area is greater than 1GB.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM IMS High Performance Load   *
    *                 for z/OS Version 2 Release 1 (FMID=H1IM210)  *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABENDS0C4 when reloading a (P)HDAM and  *
    *                      the average length of data in the       *
    *                      overflow area is greater than 1GB.      *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    ABENDS0C4 may occur when reloading a (P)HDAM and the reported
    value in  "AVERAGE LENGTH OF DATA IN DSPB(OVERFLOW)" is greater
    than 1GB. Because HP Load uses an incorrect length in creating
    the report.
    

Problem conclusion

  • HP LOAD is modified to use a correct length in creating the
    report.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK87423

  • Reported component name

    IMS HIGH PERF L

  • Reported component ID

    5655E0700

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-05-27

  • Closed date

    2009-06-09

  • Last modified date

    2009-07-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK47316

Modules/Macros

  • HPSRHRPA HPSRHRPB HPSRHRPT HPSRHRP7 HPSRHRP8
    HPSRHRP9 HPSRRPRA HPSRRPRB HPSRRPRT HPSRRPR7 HPSRRPR8 HPSRRPR9
    

Fix information

  • Fixed component name

    IMS HIGH PERF L

  • Fixed component ID

    5655E0700

Applicable component levels

  • R210 PSY UK47316

       UP09/06/15 P F906

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89F","label":"IMS HP Load"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: