Error description
Environment: - Product name (Build ID or version/patch level): IBM Rational Business Developer v7.1.0.3 Reproducible Y/N: Y Description of problem: Occasionally RBD will hang when saving an EGL file. Steps to reproduce: 1) Open an EGL file in Parts reference 2) On the parts reference, double-click on a function 3) Add a space on a comment line and save the file 4) Repeat 3 few times: RBD should hang Workaround: 1) Open the Preferences dialog (Window -? Preferences) 2) Expand the EGL preferences 3) Select Editor 4) Deselect the last check box in the Editor Preferences (Annota te errors as you type) 5) Press OK to save the preference change This will bypass the Working Copy Compiler step that is causing the hang.
Local fix
Problem summary
The problem was caused by 2 processes that formed a deadlock. One process had the WCC.lock but needed to invoke a synchronized method in the WCC. The other process was already in one of the synchronized methods of the WCC, but needed the WCC.lock.
Problem conclusion
I have change the processing, so that the lock is released and the other process is allowed to complete
Temporary fix
Comments
APAR Information
APAR number
PK85138
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-04-22
Closed date
2009-07-24
Last modified date
2009-07-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R710 PSN
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
07 December 2021