A fix is available
APAR status
Closed as new function.
Error description
In Version 3.1 of DB2 AUTOMATION Tool, users trying to use DISCARD statements with LISTDEFS are presented with a warning that LISTDEF processing is not compatible with DISCARD and the DISCARD statement is removed from the Utility. In other words, In V3.1 of DB2 Automation Tool, DISCARD statements are omitted when LISTDEFs are used. In version 2.2 of DB2 Automation Tool LISTDEFs statements were automatically turned off when the DISCARD option was used. This enhancement will change the HAA 3.1 behavior to turn off LISTDEFs when the DISCARD option is used.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Automation Tool. * **************************************************************** * PROBLEM DESCRIPTION: In Version 3.1 of DB2 AUTOMATION Tool, * * users trying to use DISCARD statements * * with LISTDEFS are presented with a * * warning that LISTDEF processing is not * * compatible with DISCARD and the DISCARD * * statement is removed from the Utility. * * In other words, In V3.1 of DB2 * * Automation Tool, DISCARD statements * * are omitted when LISTDEFs are used. In * * version 2.2 of DB2 Automation Tool * * LISTDEFs statements were automatically * * turned off when the DISCARD option was * * used. This enhancement will change the * * HAA 3.1 behavior to turn off LISTDEFs * * when the DISCARD option is used. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
Temporary fix
Comments
APPLY the PTF.
APAR Information
APAR number
PK81496
Reported component name
DB2 AUTOMATION
Reported component ID
5697G6300
Reported release
310
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2009-02-26
Closed date
2009-05-08
Last modified date
2009-06-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK46402
Modules/Macros
HAA$BUTR HAA$UREO HAA$UREX HAA#OPRI HAA#UTED HAAALA HAAREOIC HAAREORC
Fix information
Fixed component name
DB2 AUTOMATION
Fixed component ID
5697G6300
Applicable component levels
R310 PSY UK46402
UP09/05/14 P F905
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310"}]
Document Information
Modified date: