PK80033: WHEN USING SQLPA REPORT AND CHANGING SUBSYSTEM ID IT DOES NOT GIVE NEW INFORMATION FROM THE CHANGED SUBSYSTEM.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Even with PK76763 / UK42823 problem still arrises:
    . LOGON on Omegamon Classic Interface with DB2=DB2A
    . R.C.A  EDMPool Snapshot
    . PF11 zoom SQL Cache
    . PF11 zoom Authid W71A001
    . PF11 zoom SQL Statement
    . A invoke SQL PA
    . V.  View SQL PA Reports
      On the SQL PA report I see that SQL PA takes the members
      OMQCDB2A
      and OMQPDB2A --> it's ok
     Then  change the DB2 Subsystem ID on the Realtime Menu to DB2C
      . same scenario
      . but SQL PA takes always the members OMQCDB2A and OMQPDB2A
        instead of OMQCDB2C and OMQPDB2C
      .....
      Another SQLPA subtask did not get switched to the new the
     subsystem.
    

Local fix

  • Please apply the PTF when available.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   Classic Interface                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: WHEN USING SQLPA REPORT AND CHANGING    *
    *                      SUBSYSTEM ID IT DOES NOT GIVE NEW       *
    *                      INFORMATION FROM THE CHANGED SUBSYSTEM. *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    VTAM DB2 subsystem switch without using ZLOG panel
    causes incorrect SQLPA display
    
    PROBLEM CONCLUSION:
    Reinit SQLPA environment when DB2 subsystem switch
    is done without using ZLOG panel
    

Problem conclusion

  • Reinit SQLPA environment when DB2 subsystem switch
    is done without using ZLOG panel
    
    KEYWORDS : SQLPA DB2 ZLOG VTAM
    

Temporary fix

  • Switch DB2 subsystem using VTAM ZLOG panel
    

Comments

APAR Information

  • APAR number

    PK80033

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-02-04

  • Closed date

    2009-03-24

  • Last modified date

    2009-04-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK45168

Modules/Macros

  • KO2NDRVB KO2ODINB KO2OEVCB KO2OSQPB KO2PWHCB
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R410 PSY UK45168

       UP09/03/31 P F903

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: