Error description

  • DB2 V8 has raised the OPx BUFSIZE limit to 16000K. The OMPE ICAT
    configuration and Historical collector officially support the V7
    limit of 2000K.
    This APAR changes this 2000K limit in ICAT and document that
    16000K will only work for DB2 V8 and above.   The new limit will
    be used on the BUFSIZE(xxxxx) parameter of the -START TRACE
    command issued during historical collector initialization.
    
    NTH Near Term History COPTxxxx
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   OMEGAMON collector                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: Historical Collector increase           *
    *                      BUFSIZE limit to 16384.                 *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    DB2 V8 and above support BUFSIZE up to 16384 on the
    -START TRACE command.
    
    PROBLEM CONCLUSION:
    Add internal support for large BUFSIZE.
    

Problem conclusion

Temporary fix

Comments

  • Add internal support for large BUFSIZE.
    
    KEYWORDS : BUFSIZE HISTORICAL COLLECTOR
    

APAR Information

  • APAR number

    PK79971

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-02-05

  • Closed date

    2009-05-27

  • Last modified date

    2012-01-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • DUMM1KO2
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R410 PSN UK46871

       UP09/05/29 P F905

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]