IBM Support

PK76122: ENHANCEMENT CHANGES TO MESSAGES FPEV0158W AND FPEV0162W. THE MESSAGE CHANGES REFLECT CYCLE TASKS NOT HIGH CPU

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The following messages will be modified to provide a better
    context based on the SERVER task usages.
    .
    FPEV0158W DB2A 18:29:33.92 DATA SERVER DETECTED HIGH CPU USAGE
    (78%) OF TASK FPEVDB2I
    
    will be changed to say:
    FPEV0158W DB2A 18:29:33.92 DATA SERVER DETECTED HIGH CYCLE TASK
    (78%) IN FPEVDB2I
    
    Message:
    
    FPEV0162W DSNA 18:29:33.92 TRACES ARE STARTED FOR FURTHER
    ANALYSIS OF HIGH CPU USAGE
    
    Will be changed to say:
    FPEV0162W DB2A 18:29:33.92 TRACES ARE STARTED FOR FURTHER
    ANALYSIS OF HIGH SUBTASK USAGE.
    .
    The corresponding Messages and codes manual will also be updated
    to include the changes.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   PE Server subtask                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: The message FPEV0158W and FPEV0162W of  *
    *                      PE Server subtask require to be more    *
    *                      precise                                 *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    see Problem Description
    
    PROBLEM CONCLUSION:
    The OMEGAMON Server subtask PESERVER periodically monitors the
    CPU cycle consumption of its subtasks in intervals of one
    minute. If the CPU cycle consumption of a subtask exceeds an
    internal threshold value, the server issues message FPEV0158W.
    The threshold value may vary with situation and subtask. Cycle
    usage is not % usage of total system CPU, but is the % usage of
    the max CPU available to that task - typically % usage of a
    single CPU. Additionally, the internal server traces are started
    and message FPEV0162W is issued. If the cycle consumption of the
    subtask falls below the threshold within the next sample
    interval, the internal traces are switched off and normal
    processing continues. If the CPU consumption of the subtask
    remains above the threshold within the next sample interval,
    a dump is taken and message FPEV0159W is issued. If the cycle
    consumption of the subtask continues to exceed the threshold,
    the subtask will finally be reattached and message FPEV0161W is
    issued.
    

Problem conclusion

  • The OMEGAMON Server subtask PESERVER periodically monitors the
    CPU cycle consumption of its subtasks in intervals of one
    minute. If the CPU cycle consumption of a subtask exceeds an
    internal threshold value, the server issues message FPEV0158W.
    The threshold value may vary with situation and subtask. Cycle
    usage is not % usage of total system CPU, but is the % usage of
    the max CPU available to that task - typically % usage of a
    single CPU. Additionally, the internal server traces are started
    and message FPEV0162W is issued. If the cycle consumption of the
    subtask falls below the threshold within the next sample
    interval, the internal traces are switched off and normal
    processing continues. If the CPU consumption of the subtask
    remains above the threshold within the next sample interval,
    a dump is taken and message FPEV0159W is issued. If the cycle
    consumption of the subtask continues to exceed the threshold,
    the subtask will finally be reattached and message FPEV0161W is
    issued.
    
    KEYWORDS :
    FPEV0158W FPEV0162W HIGH CPU USAGE
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK76122

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-11-20

  • Closed date

    2009-01-22

  • Last modified date

    2009-02-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK43379

Modules/Macros

  • DGOVMSTR FPEUFFER FPEUFFE2 FPEUFIOI FPEUFIO2
    FPEUFOCR FPEUFOC2 FPEUFUIS FPEUFUIT FPEUFUNI FPEUFUN2 FPEUFWMG
    FPEUFWMX FPEUFYDY FPEUFYD2 FPEUFYLD FPEUFYST FPEUFYS2 FPEUIFCI
    FPEUIFC2 FPEUMSGS
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R410 PSY UK43379

       UP09/01/24 P F901

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
02 February 2009