IBM Support

PK76076: ABEND878-10 AND/OR ABEND0C4 IN CKZ00545

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Abend878-10 and/or Abend0C4 in CKZ00545 may occur when there
    are hundreds of tables in a single table space. The code has
    been changed to handle more than 1400 object id changes per
    space.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Cloning Tool.                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: Abend878-10 and/or Abend0C4 in          *
    *                      CKZ00545 may occur when there are       *
    *                      hundreds of tables in a single table    *
    *                      space. The code has been changed to     *
    *                      handle more than 1400 object id         *
    *                      changes per space.                      *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK76076

  • Reported component name

    DB2 CLONING TOO

  • Reported component ID

    5655N1000

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-11-19

  • Closed date

    2009-02-03

  • Last modified date

    2009-03-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    CKZ00763
    

Fix information

  • Fixed component name

    DB2 CLONING TOO

  • Fixed component ID

    5655N1000

Applicable component levels

  • R210 PSY UK43743

       UP09/02/11 P F902

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0"}]

Document Information

Modified date: