PK75743: INACTIVE THREADS INFO IS MISSING IN ZINACT SCREEN

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • No inactive threads information is available in ZINACT classic
    screen after UK37808. DB2 command -DIS THREAD(*) TYPE(INACTIVE)
    shows threads existence.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   Classic Interface                        *
    *                 -   CUA Interface                            *
    ****************************************************************
    * PROBLEM DESCRIPTION: Incorrect inactive thread display       *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    Inactive thread data from IFI interface is not correct
    
    PROBLEM CONCLUSION:
    Collect inactive thread data from DB2 control blocks.
    

Problem conclusion

  • Collect inactive thread data from DB2 control blocks.
    
    KEYWORDS : INACTIVE THREAD
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK75743

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-11-17

  • Closed date

    2008-11-21

  • Last modified date

    2008-12-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK41777

Modules/Macros

  •    KO2CT2IA KO2CT2IS KO2CT2I2 KO2OTHRB
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R410 PSY UK41777

       UP08/11/22 P F811

Fix is available