A fix is available
APAR status
Closed as program error.
Error description
OB0910: Program Check - Recovery Successful-OMEM+076Coccurs when in the 'DISTRIBUTED DATA FACILITY VTAM SUMMARY' panel Using the classical interface monitor (panelid ZDFVS), error occurs after applying PK44933. The abend in KO2OMEMB is caused by the return area from C2DFVS being too large. Additional symptoms: Symptom Symptom data Explanation --------------- ------------- ----------- PIDS/5655OPE00 5655OPE00 Component identifier RIDS/KO2OCNTB#L KO2OCNTB#L Routine identifier RIDS/O2OMEM O2OMEM Routine identifier ADRS/00076C 00076C Storage address LVLS/410 410 Program product release level PSW 2D812E58. KO2OCNTB+012CE0 IN EXTENDED PRIVATE at 2D812060 D6F2D6E2 D5D74040 40E5F4F1 F0F2F1F0 | O2OSNP V410210 | F1F161F2 F761F0F7 40F1F77A F3F513C0 | 11/27/07 17:35. | D7D2F5F9 F9F7F540 C4C2F2C3 D6D44040 | PK59975 DB2COM | C3D6D4C3 D6D44040 4DC35D40 C3D6D7E8 | COMCOM (C) COPY | D9C9C7C8 E340C9C2 D440C3D6 D9D74B40 | RIGHT IBM CORP. | F2F0F0F5 40404040 90ECD00C 18AF4120 | 2005 ..ü..... | SYSTRACE: *PGM 003 077D2000 AD802FA4 00040003 00000000 009C4000 ... SSRV 78 813222E0 4000E700 00000BB8 1A11D248 Getmain SSRV 78 8132330C 4000E703 00000BB8 1A11D248 Freemain PR ... 0 2D812E07 0132338C SSAR ... 00C1 SVC 33 070D1000 AD812E58 00000000 31E5BAD0 31E5B9E8 Snap/Sdu *PGM PSW=AD802FA4 points to ..KO2O0951E OMEM - Private Storage Exhausted Just before ABEND storage length x'0BB8' at address 1A11D248 was GETMAINed and and FREEMAINed -- with an eyecatcher ASRWAQE. JOB=CANSO2 failed in LMOD=KO2OCNTB#L CSECT=O2OMEM at OFFSET=00076C. The ABEND0C3 in KO2OMEMB in intentional issued when above the line storage is exhausted, this prevents storage below the line from being used up as well.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - Classic Interface * * - CUA Interface * **************************************************************** * PROBLEM DESCRIPTION: Data collection routine returned * * invalid length for return data. * * * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: Return code 4 from data collection routine should return zero length data. PROBLEM CONCLUSION: Correct return code and return area length.
Problem conclusion
Correct return code and return area length. KEYWORDS : RETURN AREA LENGTH INVALID
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PK74262
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
YesPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-10-22
Closed date
2008-10-29
Last modified date
2017-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK41148 UK41149
Modules/Macros
KO2CDFCA KO2CDFCS KO2CDFC2 KO2ODSTB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
04 February 2017