A fix is available
APAR status
Closed as program error.
Error description
OBJECT COMPARE 720, RESTRICT THE USE OF CLONED TABLES, XML AND HIDDEN COLUMNS FOR DB2 V9
Local fix
APPLY PTF
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Object Compare Tool V7.2 * * running on DB2 V9 in new function mode. * **************************************************************** * PROBLEM DESCRIPTION: Data in clone tables is not unloaded * * when the base table is to be dropped. * * Hidden columns are not unloaded when * * using HPU or DSNTIAUL. * * * * Incomplete or incorrect DDL is created * * for objects with clone tables, hidden * * columns, or extended index types. * * * * ALC operations against objects with new * * data types(XML, BIGINT, DECFLOAT, INARY * * or VARBIN) may lead to errors. Rename * * database against an implicit database * * is invalid. * **************************************************************** * RECOMMENDATION: Apply The PTF. * **************************************************************** Objects with certain DB2 V9 characteristics may not be completely unloaded nor their DDL completely recreated.
Problem conclusion
Operations are disallowed against objects with the above characteristics. The following message is displayed when such a condition occurs: At least one of the following conditions exists that prevents continuing the operation. - a clone table exists - an implicitly hidden column exists - an extended index type exists - the database is implicitly created - an XML, BIGINT, DECFLOAT, BINARY or VARBIN data type The Object Compare step will end with a return code of 8.
Temporary fix
Comments
APAR Information
APAR number
PK73206
Reported component name
DB2 OBJECT COMP
Reported component ID
5697G6400
Reported release
720
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-10-03
Closed date
2009-04-06
Last modified date
2009-05-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
GOC2CMF GOC2CMP GOC2CMR GOC2CMS GOC2CMT H25G720J
Fix information
Fixed component name
DB2 OBJECT COMP
Fixed component ID
5697G6400
Applicable component levels
R720 PSY UK45542
UP09/04/10 P F904
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUVH","label":"IBM Db2 Object Comparison Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]