IBM Support

PK73206: OBJECT COMPARE 720, RESTRICT THE USE OF CLONED TABLES, XML AND HIDDEN CLOUMNS FOR DB2 V9 NFDB29

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • OBJECT COMPARE 720, RESTRICT THE USE OF CLONED TABLES, XML AND
    HIDDEN COLUMNS FOR DB2 V9
    

Local fix

  • APPLY PTF
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of  DB2 Object  Compare Tool V7.2      *
    *                 running on DB2 V9 in new function mode.      *
    ****************************************************************
    * PROBLEM DESCRIPTION: Data in clone tables  is not unloaded   *
    *                      when the base table is to be dropped.   *
    *                      Hidden columns  are not unloaded when   *
    *                      using HPU or DSNTIAUL.                  *
    *                                                              *
    *                      Incomplete or incorrect DDL is created  *
    *                      for objects  with clone tables, hidden  *
    *                      columns, or extended index types.       *
    *                                                              *
    *                      ALC operations against objects with new *
    *                      data types(XML, BIGINT, DECFLOAT, INARY *
    *                      or VARBIN) may lead to errors.   Rename *
    *                      database  against an implicit  database *
    *                      is invalid.                             *
    ****************************************************************
    * RECOMMENDATION: Apply The PTF.                               *
    ****************************************************************
    Objects with  certain DB2 V9 characteristics may not be
    completely unloaded nor their DDL completely recreated.
    

Problem conclusion

  • Operations are disallowed against objects with the above
    characteristics. The following message is displayed when
    such a condition occurs:
    
    At least one of the following conditions exists that prevents
    continuing the operation.
    
      - a clone table exists
      - an implicitly hidden column exists
      - an extended index type exists
      - the database is implicitly created
      - an XML, BIGINT, DECFLOAT,
        BINARY or VARBIN data type
    
    The Object Compare step will end with a return code of 8.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK73206

  • Reported component name

    DB2 OBJECT COMP

  • Reported component ID

    5697G6400

  • Reported release

    720

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-10-03

  • Closed date

    2009-04-06

  • Last modified date

    2009-05-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    GOC2CMF  GOC2CMP  GOC2CMR  GOC2CMS  GOC2CMT
    H25G720J
    

Fix information

  • Fixed component name

    DB2 OBJECT COMP

  • Fixed component ID

    5697G6400

Applicable component levels

  • R720 PSY UK45542

       UP09/04/10 P F904

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUVH","label":"IBM Db2 Object Comparison Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 February 2021