IBM Support

PK72401: WITH VSAMSEQ ON NTH FILES MGMTCLAS AND UNIT BUT THESE ARE NOT BEING COPIED OVER TO COPT MEMBER MANAGEMENT CLASS STORAGE CLASS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When using VSAMSEQ on Near Term History files NTH inputing the
    mgmtclas and unit does not get saved in the COPT member.
    Customer's input:
                                                 Volser    Storclas/
     Dataset names                               Unit      Mgmtclas
     ITMZTEMS.RKD2SEQ.@DB2.@DATE.@TIME______     IX3009    ________
                                                 3390____  MC040035
     Primary space    ==> 50__ (3-9999 cylinders)
     Secondary space  ==> 0___ (0-9999 cylinders)
    .
    Put MGMTCLAS and UNIT and STORAGE CLASS were not saved or copied
    into the COPT member.
    

Local fix

  • Please apply PTF when available.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   ICAT                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: UNIT, STORAGE CLASS and MANAGEMENT      *
    *                      CLASS values may be specified in        *
    *                      panels for VSAMSEQ(DYNAMIC) and         *
    *                      VSAMSEQ(GDG) selection of NTH           *
    *                      configuring, but no values are          *
    *                      appeared in COPT member                 *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    UNIT, STORAGE CLASS and MANAGEMENT CLASS values may be
    specified in panels for VSAMSEQ(DYNAMIC) and
    VSAMSEQ(GDG) selection of NTH configuring, but this
    information does not go into the COPT member
    therefore can not be used by the Data Collector for
    dataset allocation.
    
    PROBLEM CONCLUSION:
    Add values for UNIT, STORAGE CLASS and MANAGEMENT CLASS
    if specified into the COPT member produced by ICAT.
    Support it for VSAMSEQ(DYNAMIC) and VSAMSEQ(GDG).
    

Problem conclusion

  • Add values for UNIT, STORAGE CLASS and MANAGEMENT CLASS
    if specified into the COPT member produced by ICAT.
    Support it for VSAMSEQ(DYNAMIC) and VSAMSEQ(GDG).
    
    KEYWORDS : UNIT STORAGE CLASS MANAGEMENT CLASS
               VSAMSEQ(DYNAMIC) VSAMSEQ(GDG)
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK72401

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-09-18

  • Closed date

    2008-12-18

  • Last modified date

    2017-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    022PC5Ÿ UK42615

Modules/Macros

  •    KD261SN2 KO2$QIOB KO2ACAPA KO2ACAPS KO2ACAP2
    KO2CMVSC KO2CMVSF KO2CNSRB KO2DAUDA KO2DAUDS KO2DAUD2 KO2DDSBA
    KO2DDSBS KO2DDSB2 KO2DMSCA KO2DMSCS KO2DMSC2 KO2DTHDA KO2DTHDS
    KO2DTHD2 KO2DXSTB KO2DXS1A KO2DXS1S KO2DXS12 KO2DXS2A KO2DXS2S
    KO2DXS22 KO2HDTIB KO2HDTPB KO2HINTB KO2HPRCB KO2HPR1B KO2HPR2B
    KO2HSQIB KO2HSQPB KO2HVINB KO2HWLMB KO2ICOLA KO2ICOLS KO2ICOL2
    KO2IINTB KO2LCAPB KO2OH2IB KO2ONTAB KO2TSB1B KO2TSB2B KO2TSB3B
    KO2TSB4B KO2WGETB
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R410 PSY UK42615

       UP08/12/20 P F812

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]