A fix is available
APAR status
Closed as program error.
Error description
User gets FATAL ERROR on Complete Config ICAT on panel KD261MCU Doing the "Complete the configuration" KCICBRWS *************************************** KCICBRWS FATAL ERROR DETECTED, RC = 20 KCICBRWS FUNCTION: UNKNOWN KCICBRWS Output overflow KCICBRWS Line to be written greater than data set LRECL (80), KD261DC1 record-874 KCICBRWS *************************************** KCICSTMC *************************************** KCICSTMC FATAL ERROR DETECTED, RC = 24 KCICSTMC FUNCTION: UNKNOWN KCICSTMC ***************************************
Local fix
Tempory workaround: option1 ) The customer can either directly look into the TKANCUS member KD261DC3 which contains an uncustomized Complete the configuration text (that we display for z/OS 1.4 customers). This is plain text without variables. option 2) To use the customized Complete the configuration, the customer parameter in the following 2 places. in the following 2 places. Then the 2 variables are 000873 トNote:チYou can log on to the VTAM Classic interface by using "logon 000874 applid(&APPLID)". In this case, the virtual terminal pool <-- in this line remove &APPLID, this is the variable that contains the Classic Interface applid 000875 definitions are not required. ----- and ------- 000885 VTAM Classic interface via ISPF. They are not already defined if 000886 you get the message: 000887 "SESSION REQUEST FAILED - OBVTAM APPL &APPLID NOT AVAILABLE" <-- in this line remove &APPLID,this is the variable that contains the Classic Interface applid . Please apply PTF when it becomes available.
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - ICAT * **************************************************************** * PROBLEM DESCRIPTION: When system variable support is used * * maximum length for the variable * * value is needed. In such case * * text line becomes too long. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: The problem is caused by the VTAM APPLID variable. When system variable support is used maximum length for the variable value is needed. In such case text line becomes too long. PROBLEM CONCLUSION: Split lines containing long variables in two parts.
Problem conclusion
Split lines containing long variables in two parts. KEYWORDS : FATAL ERROR KD261DC1
Temporary fix
Comments
APAR Information
APAR number
PK71199
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-08-27
Closed date
2008-09-24
Last modified date
2008-10-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK40124
Modules/Macros
KD261DC1
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R410 PSY UK40124
UP08/09/26 P F809
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
03 October 2008