Error description

  • User gets FATAL ERROR on Complete Config ICAT on panel KD261MCU
    Doing the "Complete the configuration"
    KCICBRWS ***************************************
    KCICBRWS FATAL ERROR DETECTED, RC = 20
    KCICBRWS FUNCTION: UNKNOWN
    KCICBRWS Output overflow
    KCICBRWS Line to be written greater than data set LRECL (80),
        KD261DC1 record-874
    KCICBRWS ***************************************
    KCICSTMC ***************************************
    KCICSTMC FATAL ERROR DETECTED, RC = 24
    KCICSTMC FUNCTION: UNKNOWN
    KCICSTMC ***************************************
    

Local fix

  • Tempory workaround:
     option1 ) The customer can either directly look into the
               TKANCUS member KD261DC3 which contains an
               uncustomized Complete the configuration text
               (that we display for z/OS 1.4 customers). This is
               plain text without variables.
     option 2) To use the customized Complete the configuration,
               the customer parameter in the following 2 places.
               in the following 2 places. Then the 2 variables are
    000873  トNote:チYou can log on to the VTAM Classic interface by
            using "logon
    000874  applid(&APPLID)". In this case, the virtual terminal
            pool <-- in this line remove &APPLID, this is the
            variable that contains the Classic Interface applid
    000875  definitions are not required.
        ----- and  -------
    000885  VTAM Classic interface via ISPF. They are not already
            defined if
    000886  you get the message:
    000887 "SESSION REQUEST FAILED - OBVTAM APPL &APPLID NOT
            AVAILABLE"  <-- in this line remove &APPLID,this is the
            variable that contains the Classic Interface applid
    .
    Please apply PTF when it becomes available.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   ICAT                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: When system variable support is used    *
    *                      maximum length for the variable         *
    *                      value is needed. In such case           *
    *                      text line becomes too long.             *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    The problem is caused by the VTAM APPLID variable.
    When system variable support is used maximum length for the
    variable value is needed. In such case text line becomes
    too long.
    
    PROBLEM CONCLUSION:
    Split lines containing long variables in two parts.
    

Problem conclusion

  • Split lines containing long variables in two parts.
    
    KEYWORDS : FATAL ERROR KD261DC1
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK71199

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-08-27

  • Closed date

    2008-09-24

  • Last modified date

    2008-10-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK40124

Modules/Macros

  • KD261DC1
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R410 PSY UK40124

       UP08/09/26 P F809

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: