IBM Support

PK70961: ABEND WHEN USING FILE I/O STORAGE FOR CONTROL BLOCK ABOVE 16MB

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Rational Business Developer V7.1 (RBD)
    The fix for PTF UK38820 (APAR PK70343) exposed a new problem.
    The control block for some files should be below the line, but
    the program logic was acquiring the storage above the line. The
    previous defect was causing all storage to be obtained below 16
    MB. Once that defect was fixed, the control block is now
    obtained above 16MB, causing an abend in certain scenarios using
    file input/output.
    

Local fix

  • N/A
    

Problem summary

  • The control block for some files should be below the line,
    but the program logic was acquiring the storage above the
    line. This caused an abend in certain scenarios using
    file i/o.
    

Problem conclusion

  • The coding error has been fixed. The affected memory is
    obtained  below 16MB
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK70961

  • Reported component name

    RATL COBOL RT Z

  • Reported component ID

    5655R2900

  • Reported release

    601

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-08-22

  • Closed date

    2008-08-25

  • Last modified date

    2008-11-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK39246

Fix information

  • Fixed component name

    RATL COBOL RT Z

  • Fixed component ID

    5655R2900

Applicable component levels

  • R038 PSY

       UP

  • R601 PSY UK39246

       UP08/10/11 P F810

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSN27B","label":"Rational COBOL Runtime for zSeries"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
03 November 2008