APAR status
Closed as program error.
Error description
In the WAS fixpacks 6.0.2.29 and 6.1.0.17 the value of the WASReqURL cookie was changed from relative URL to: http://:9082/wps/myportal , where the protocol and port info was added, but the host name is missing. Portal uses this URL as redirect URL, which does not work after the WAS change. With this fix, portal removes the first part of the URL and keeps the relative URL, just as it always worked.
Local fix
Problem summary
In the WAS fixpacks 6.0.2.29 and 6.1.0.17 the value of the WASReqURL cookie was changed from relative URL to: http://:9082/wps/myportal , where the protocol and port info was added, but the host name is missing. Portal uses this URL as redirect URL, which does not work after the WAS change.
Problem conclusion
With this fix, portal removes the first part of the URL and keeps the relative URL, just as it always worked. Failing Module(s): Engine: URL Generation Affected Users: WebSphere Portal Administrators & Users Version Information: Portal Version(s): 5.1.0.4 Pre-Requisite(s): Co-Requisite(s): --- Portal Version(s): 5.1.0.5 Pre-Requisite(s): Co-Requisite(s): --- Portal Version(s): 6.0.1.3 Pre-Requisite(s): Co-Requisite(s): --- Portal Version(s): 6.0.1.4 Pre-Requisite(s): Co-Requisite(s): --- Portal Version(s): 6.1.0.0 Pre-Requisite(s): Co-Requisite(s): --- Platform Specific: This fix applies to all platforms. A fix is available from Fix Central: http://www.ibm.com/eserver/support/fixes/fixcentral/swgquickorde r?apar=PK70705&productid=WebSphere%20Portal&brandid=5 You may need to type or paste the complete address into your Web browser.
Temporary fix
Comments
APAR Information
APAR number
PK70705
Reported component name
WEBSPHERE PORTA
Reported component ID
5724E7600
Reported release
60A
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-08-19
Closed date
2008-10-16
Last modified date
2008-10-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBSPHERE PORTA
Fixed component ID
5724E7600
Applicable component levels
R51D PSY
UP
R51E PSY
UP
R60G PSY
UP
R60H PSY
UP
R610 PSY
UP