PK70420: FUNTDB01 PRECEEDED BY AN ABEND IN A PORT TASK

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If an IMS Connect PORT task abends and BPE abended the other
    PORT tasks, a loop in FUNTDB01 may occur. This is because BPE
    abended a PORT task while a latch was held by FUNTDB01. The
    Abend prevented the latch from being released by the task.
    This caused a CEX non-PORT task to loop trying to obtain the
    latch left by the abending PORT task.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of the Functional Support Library  *
    *                 V2.1.                                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: FUNTDB01 preceeded by an abend in a     *
    *                      PORT task.                              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    If an IMS Connect Port task abends in a system with
    mulitple ports defined, a loop in module FUNTDB01 can
    occur. The loop is a spin lock loop trying to obtain
    a buffer latch held by the abending Port task.
    

Problem conclusion

  • The emergency termination process has been changed to
    make sure that the buffer latch can be released for
    the abending Port task.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK70420

  • Reported component name

    FUNC SUPP LIBRA

  • Reported component ID

    5655K4801

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-08-11

  • Closed date

    2008-09-22

  • Last modified date

    2008-10-03

  • APAR is sysrouted FROM one or more of the following:

    PK70417

  • APAR is sysrouted TO one or more of the following:

    UK40092

Modules/Macros

  •    FUNTDB01
    

Fix information

  • Fixed component name

    FUNC SUPP LIBRA

  • Fixed component ID

    5655K4801

Applicable component levels

  • R210 PSY UK40092

       UP08/09/25 P F809