If an IMS Connect PORT task abends and BPE abended the other PORT tasks, a loop in FUNTDB01 may occur. This is because BPE abended a PORT task while a latch was held by FUNTDB01. The Abend prevented the latch from being released by the task. This caused a CEX non-PORT task to loop trying to obtain the latch left by the abending PORT task.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Users of IMS Connect Extensions V1.2. * **************************************************************** * PROBLEM DESCRIPTION: FUNTDB01 preceeded by an abend in a * * PORT task. * **************************************************************** * RECOMMENDATION: * **************************************************************** This APAR is correcting the following problems: 1. Loop in FUNTDB01 if PORT task abends when multple ports are defined. 2. Abend 0c4 may occur in CEXTECL1 during init trying to issue CEX internal trace. 3. IMS Connect may abend 052 during initialization if the local port is present and publisher api is active.
Problem conclusion
1. Correct emergency termination code to ensure that the TDB buffer lock can be freed for an abending port task. 2. Change module CEXTECL1 to use a proper control block address to determine if the CEX internal trace has been requested 3. Delay initialization of the Publisher API until the local port has completed initialzation. This ensures the AXSET done by CEX is after the AXSET done by IMS Connect for the local port.
Temporary fix
Comments
APAR Information
APAR number
PK70418
Reported component name
IMS CONNECT EXT
Reported component ID
5655K4800
Reported release
120
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-08-11
Closed date
2008-11-19
Last modified date
2008-12-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK41715
Modules/Macros
CEXEVTPR CEXMAIN CEXPUBMN CEXR163 CEXTECL CEXTECL1 CEXTPLST
Fix information
Fixed component name
IMS CONNECT EXT
Fixed component ID
5655K4800
Applicable component levels
R120 PSY UK41715
UP08/11/25 P F811
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88S","label":"IMS Connect Extensions"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"120"}]
Document Information
Modified date:
22 October 2020