A fix is available
APAR status
Closed as program error.
Error description
ABEND0C4 occurs in IMS Sysplex Manager Server module GJEULLK0.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMSSM 1.3 * **************************************************************** * PROBLEM DESCRIPTION: If an IMS is involved in an IRLM * * longlock cycle, but the IMS is on hold, * * because it is waiting on archiving the * * logs-this IMS is not receiving the long * * lock messages from IRLM . In such cases * * the server can not build the whole long * * lock record and an abend 0C4 occures. * * Abend is in GJEULLK0. * **************************************************************** * RECOMMENDATION: * **************************************************************** 0C4 in server address space, if some IMSs involved in longlock cycles are on hold and are not receiving the IRLM messages. Server can not build the whole longlock record with top blockers, blockers and waiters and an abend 0C4 occures.
Problem conclusion
Problem is fixed- the server creates a short record from the available IRLM messages.
Temporary fix
Comments
APAR Information
APAR number
PK68388
Reported component name
IMS SYSPLEX MGR
Reported component ID
5655P0100
Reported release
130
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-06-30
Closed date
2008-07-02
Last modified date
2008-08-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK37819
Modules/Macros
GJEULLK0
Fix information
Fixed component name
IMS SYSPLEX MGR
Fixed component ID
5655P0100
Applicable component levels
R130 PSY UK37819
UP08/07/04 P F807
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8AA","label":"IMS Sysplex Manager"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.3.0"}]
Document Information
Modified date:
03 October 2020