IBM Support

PK67506: OMPE V410: SQLPA JCL PROBLEMS IN NON-SMS ENVIRONMENTS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Cust env: z/OS V1.8, DB2 V8, OmPE V410, ITM V6.1
    Cust problem:
    I have customized the SQLPA for OMEGAMON XE for DB2.  But when
    I go into the classical Interface and select 'V' for the SQLPA
    Report it shows failure for not be able to show the report.
    I had noticed that we need to enable the Performance Warehouse
    in order for SQLPA to work. I have done that and seeing the
    message of below:
    PERFORMANCEWAREHOUSE=YES
      - PERFORMANCEWAREHOUSEADDRESSSPACENAME=DT11PWH
    and follows the message of
    FPEV5005I  DT11 DATABASE UPDATE COMPLETE
    In the classical Interface, the SQL PA Analysis: Available
    Reports shows failure:
    IEF210I DT11PWH ANLSTEP1 FPEZPWH ANLREP - UNIT FIELD SPECIFIES
    INCORRECT DEVICE NAME
    Please let me know if there is anything that I needed
    to be done in order to activate the report. By the way, the
    SQLPA works ok by itself if I used SPUFI interface
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - PE Server                                  *
    *                 - Classic Interface                          *
    *                 - Performance Warehouse user                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: When SQLPA is requested from            *
    *                      Classic Interface in non-SMS            *
    *                      environment the execution of started    *
    *                      job created in the PWH for SQLPA        *
    *                      is failed.                              *
    *                      In the corresponding job output an      *
    *                      error is reported as UNIT FIELD         *
    *                      SPECIFIES INCORRECT DEVICE NAME.        *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    There is no way to define a DSVOLUME and DSUNIT value
    required for non-SMS environment within OMPEMSTR because
    the corresponding JCL parameters for SQLPA are not generated.
    
    PROBLEM CONCLUSION:
    Change SQLPA jcl skeletons to support new common approach
    for handling DSVOLUME and DSUNIT values.
    
    KEYWORDS:
    PWH SQLPA DATASERVERVOLUME DATASERVERUNIT
    DSVOLUME DSUNIT UNIT VOLUME SMS NONSMS
    

Problem conclusion

  • PROBLEM CONCLUSION:
    Change SQLPA jcl skeletons to support new common approach
    for handling DSVOLUME and DSUNIT values.
    
    KEYWORDS:
    PWH SQLPA DATASERVERVOLUME DATASERVERUNIT
    DSVOLUME DSUNIT UNIT VOLUME SMS NONSMS
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK67506

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-06-12

  • Closed date

    2008-07-15

  • Last modified date

    2008-08-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK38134

Modules/Macros

  •    DGO@SQPA DGOVMSTR DGOZSQPA
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R410 PSY UK38134

       UP08/07/17 P F807

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410"}]

Document Information

Modified date:
31 March 2021