Error description

  • EXPLAIN: remove unnecessary grants, correct CTC steps
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   ICAT                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. In the GRANT job for EXPLAIN         *
    *                      privileges are granted that are not     *
    *                      needed for the EXPLAIN function         *
    *                      (DISPLAY, TRACE, MONITOR1, MONITOR2)    *
    *                                                              *
    *                      2. In 'Complete the configuration' in   *
    *                      step 'Activate SOURCE EXPLAIN' the      *
    *                      variable for hlq3.1 is not expanded     *
    *                      correctly.                              *
    *                                                              *
    *                      3. The verification for batch           *
    *                      reporting is not generated by ICAT      *
    *                      and therefore not customized. It is     *
    *                      not documented that in case of an RTE   *
    *                      of type SMP/E Sharing the libraries     *
    *                      have to be renamed, for example         *
    *                      RKO2DATA to TKO2DATA.                   *
    *                                                              *
    *                      4. When 'Automatic Exception            *
    *                      Processing' is configured for the first *
    *                      time the specified values are not       *
    *                      stored.                                 *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    1. In the GRANT job for EXPLAIN privileges are granted that are
    not needed for the EXPLAIN function (DISPLAY, TRACE, MONITOR1,
    MONITOR2)
    
    2. In 'Complete the configuration' in step 'Activate SOURCE
    EXPLAIN' the variable for hlq3.1 is not expanded correctly.
    
    3. It is not documented that in case of RTEs of type SMP/E
    Sharing libraries referenced in the job have to be renamed,
    for example RKO2DATA to TKO2DATA.
    
    4. When 'Automatic Exception Processing' is configured for the
    first time the specified values are not stored.
    
    PROBLEM CONCLUSION:
    1. Privileges that are not required are removed from the GRANT
    job.
    2. In 'Complete the configuration' in step 'Activate SOURCE
    EXPLAIN' the variable for hlq3.1 is set to
    <HLQ of the RTE>.<RTE Name>
    
    3. In the job header a note is added for documentation.
    
    4. Indention is corrected.
    

Problem conclusion

  • 1. Privileges that are not required are removed from the GRANT
    job.
    2. In 'Complete the configuration' in step 'Activate SOURCE
    EXPLAIN' the variable for hlq3.1 is set to
    <HLQ of the RTE>.<RTE Name>
    
    3. In the job header a note is added for documentation.
    
    4. Indention is corrected.
    
    KEYWORDS : ICAT EXPLAIN GRANT HLQ3.1 EXCEPTION PROCESSING
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK66921

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-06-03

  • Closed date

    2008-07-07

  • Last modified date

    2017-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK37847

Modules/Macros

  •    FPEJIVPA KD261DC1 KD261PY  KD261SEX
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R410 PSY UK37847

       UP08/07/10 P F807 Ø

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
04 February 2017