Error description

  • Abend may occur in DB2 V9 when running DB2 Query Monitor
    concurrently with Omegamon, with Omegamon Object Analysis
    feature enabled. Active Application may abend with U3590.
    
    OTHER KEYWORD:  5655OPE00
    

Local fix

  • To turn off OM DB2 Object Analysis in Omegamon:
    
    If all subsystems on the LPAR are DB2 V9 then all three steps
    below should be followed.
    
    1) In the RKD2PAR(U) library, allocated to the
       RKANPAR DD, find the member with the same name
       as the started task.
    
    2) In this member find the line that reads EXEC EMGRsmfid
       and comment out by placing an * in column 1.
       This will prevent the event manager for that
       LPAR (smfid) from starting. This is the underlying
       collector for Object Analysis.
    
    3) Find any lines that read EXEC smfiddb2id and
       comment out by placing an * in column 1.
       This will prevent the Object Analysis feature from
       starting for the specific DB2 (db2id) on the particular
       LPAR (smfid).  (smfiddb2id is the concatenation of
       the LPAR and DB2 subsystem ids)
    
    Save the changes and start the OMEGAMON DB2.
    
    
    If there is a mix of DB2 V7, V8 and V9 running on the LPAR
    and you wish to have Object Analysis available for the
    non-V9 subsystems, do not perform step 2. Only perform
    step 3 for the DB2 V9 subsystems.
    Test Query Monitor.
    
    ** Please be aware these changes are being made outside
       of ICAT. If ICAT is reinvoked, it is possible that
       these changes will be undone, unless appropriate
       configuration changes are made in ICAT.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Query Monitor.                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: Abend may occur in DB2 V9 when running  *
    *                      DB2 Query Monitor concurrently with     *
    *                      Omegamon, with Omegamon Object          *
    *                      Analysis feature enabled. Active        *
    *                      Application may abend with U3590.       *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    PK58356

  • Reported component name

    DB2 QUERY MONIT

  • Reported component ID

    5655E6701

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2007-12-17

  • Closed date

    2008-03-04

  • Last modified date

    2008-04-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    CQMOXG91
    

Fix information

  • Fixed component name

    DB2 QUERY MONIT

  • Fixed component ID

    5655E6701

Applicable component levels

  • R220 PSY UK34258

       UP08/03/07 P F803 Ž

  • R221 PSY UK34259

       UP08/03/07 P F803 Ž

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220"}]