APAR status
Closed as new function.
Error description
Enhance FPO ODE (Online Data Extract) to support the FP Randomizer XCI interface that was provided by IMS V10 PK40256. This is a forward fit of HPFPU V3R1 FPO APAR PK56199.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All using FP randomizer XCI interface for * * users of High Performance Fast Path * * Utilities Online Data Extract Version 3 * * Release 2 (FMID: H31A320). * **************************************************************** * PROBLEM DESCRIPTION: Forward Fit APAR of FP0 V3R1 PK56199: * * FPO ODE supports FP Randomizer XCI * * interface for Batch provided by IMS V10 * * PK40256. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** Forward Fit APAR of FP0 V3R1 PK56199: FPO ODE supports FP Randomizer XCI interface for Batch provided by IMS V10 (5635-A01) PK40256.
Problem conclusion
Temporary fix
Comments
======================== = DOCUMENTATION CHANGE = ======================== The IMS High Performance Fast Path Utilities for z/OS User's Guide Volume 3: Fast Path Online Tools Version 3 Release 2 (SC18-9871-03). Appendix G. Messages and codes Messages The following messages should be changed as follows: FPX0064W Randomizer is not loaded. Full area scan will be used. Explanation: The randomizer has not been loaded. A full area scan will be performed. System action: Processing continues and a full area scan will | be done. Processing ends with a return code of 4. User response: This is a warning message. Check that the randomizer is included in the load module in STEPLIB. ---------------------------------------------------------------- FPX0065W Randomizer returned correct area # but invalid RAP | number. Full area scan will be used. Explanation: The randomizer was successfully loaded and selected the proper DMAC; however, the RAP number was not within the RAA range. | System action: Processing continues and a full area scan will | be done. Processing ends with a return code of 4. User response: Determine the reason why this RAP number was not within the RAA range. ---------------------------------------------------------------- FPX0067W Randomizer is AMODE(24). Must be AMODE(31). Explanation: The randomizer has been compiled/linked with AMODE(24). System action: The utility detected that the randomizer is not 31-bit capable. Processing continues to build the performance optimized UOW list using the randomizer. IMS requires all randomizers to be 31-bit capable. | Processing ends with a return code of 4. User response: This is a warning message. If possible, determine the reason the randomizer is AMODE (24) and correct the problem. ---------------------------------------------------------------- The following message should be added as follows: FPX0401W Error in call to randomizer routine rmodname FUNCTION: function name. Full area scan will be used. (cont) RETURN CODE: xxx REASON CODE: X'xxxxxxxx' Explanation: Specified randomize module returned with error. FUNCTION and REASON CODE are issued only when XCI randomizer is called. System action: Processing continues and a full area scan will be done. Processing ends with a return code of 4. Programmer response: Check the randomizer that is loaded by IMS.
APAR Information
APAR number
PK57710
Reported component name
IMS HP FP UTILI
Reported component ID
5655K9400
Reported release
320
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2007-12-05
Closed date
2007-12-11
Last modified date
2008-01-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK32120
Modules/Macros
FPXDDRVA FPXDDRV0 FPXDDRV8 FPXDDRV9 FPXDRIVA FPXDRIV0 FPXDRIV8 FPXDRIV9 FPXMBLK FPXMBLK0 FPXMSG00 FPXMXCI0 FPXTERMA FPXTERM0 FPXTERM8 FPXTERM9 FPXUXCI FPXVPRM1 H31A320J
SC18987103 |
Fix information
Fixed component name
IMS HP FP UTILI
Fixed component ID
5655K9400
Applicable component levels
R320 PSY UK32120
UP07/12/28 P F712
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89D","label":"IMS HP Fast Path Utilities"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0"}]
Document Information
Modified date:
04 October 2020