PK56626: MSGCKZ11430W DELETE FAILED, RETURN CODE=00000102 REASON CODE=00000007

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • MSGCKZ11430W DELETE FAILED, RETURN CODE=00000102 REASON
    CODE=00000007
    When using TEMPDSN(DELETE) and the source temporary data set is
    in use during RENAME can get:
    CKZ11430W DELETE FAILED, RETURN CODE=00000102 REASON
    CODE=00000007 VOLSER=VTGT82
    DSN=SYS07143.T080329.RA000.TGA.R0107997
    CKZ11430W ORIGINAL DSN=SYS07143.T080329.RA000.TGA.R0107997
    and
    IEC331I 042-006(040B0425),TGA8RENR,S1 ,SCRT,IGG0CLH0
    IEC331I VOL,VTGT82,NAME,SYS07143.T080329.RA000.TGA.R0108000
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Cloning Tool for Z/OS.          *
    ****************************************************************
    * PROBLEM DESCRIPTION: MSGCKZ11430W DELETE FAILED, RETURN      *
    *                      CODE=00000102 REASON CODE=00000007      *
    *                      When using TEMPDSN(DELETE) and the      *
    *                      source temporary data set is in use     *
    *                      during RENAME can get:                  *
    *                      CKZ11430W DELETE FAILED, RETURN         *
    *                      CODE=00000102 REASON CODE=00000007      *
    *                      VOLSER=VTGT82 DSN=SYS07143.T080329.     *
    *                       RA000.TGA.R0107997                     *
    *                      CKZ11430W ORIGINAL DSN=SYS07143.        *
    *                       T080329.RA000.TGA.R0107997             *
    *                      and                                     *
    *                      IEC331I 042-006(040B0425),TGA8RENR,S1   *
    *                       ,SCRT,IGG0CLH0                         *
    *                      IEC331I VOL,VTGT82,NAME,                *
    *                       SYS07143.T080329.RA000.TGA.R0108000    *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK56626

  • Reported component name

    DB2 CLONING TOO

  • Reported component ID

    5655N1000

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-11-15

  • Closed date

    2007-12-26

  • Last modified date

    2008-02-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    CKZ00110
    

Fix information

  • Fixed component name

    DB2 CLONING TOO

  • Fixed component ID

    5655N1000

Applicable component levels

  • R210 PSY UK32642

       UP08/01/04 P F801

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUUE","label":"IBM Db2 Cloning Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]