A fix is available
APAR status
Closed as program error.
Error description
When PE Server functions are started using operator commands, the settings for DATASERVERVOLUME and DATASERVERUNIT are ignored. OMPEMSTR
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - PE Server * * - Performance Warehouse users * * - ICAT * **************************************************************** * PROBLEM DESCRIPTION: --------------------------------------- * * PMR 54851 379 000 * * The OMPEMSTR parameter settings for * * DATASERVERVOLUME and DATASERVERUNIT are * * ignored after using PE SERVER operator * * commands. * * --------------------------------------- * * PMR 87882 001 866 * * PE SERVER msg "THE EVENT VSAM DATASET * * COULD NOT BE CREATED" occurs. * * The DEFINE CLUSTER parameter VOLUME * * is not generated. * * --------------------------------------- * * PMR 03677 499 000 * * The SMS ACS routine do not accept * * the DEFINE CLUSTER parameter VOLUME(*) * * for dataset work-hlq.EVENTS. PE SERVER * * msg "VSAM dataset creation failed" * * occurs. * * --------------------------------------- * * PMR 66216 035 724 * * The generated PWH bind job PMDBBIND * * fails, because the JCL parameters * * UNIT and VOLUME=SER are commented out * * or an invalid JCL card * * "VOLUME=SER= * ,UNIT=(SAPPL)" * * is created. * * --------------------------------------- * * PMR 48244 379 000 * * Bind package DBO@CHKB fails if the * * PE SERVER is started with option PWH=F * * and option AUTODETECT=Y. * * --------------------------------------- * * More ... * * After using the STC modify command * * DISPLAY=(PARMS) no further dynamic bind * * of PWH DBRMs is possible, because the * * JCL parameters VOL=SER and UNIT are * * commented out. * * --------------------------------------- * * More ... * * After using the STC modify command * * DISPLAY=(PARMS) the VSAM datasets * * HISTORY and EVENTS are not allocated * * dynamically in a Non-SMS environment. * * --------------------------------------- * * More ... * * For the ICAT specified value blank for * * DATASERVERVOLUME the OMPEMSTR parameter * * DATASERVERVOLUME=" * " is created. * * The resulting JCL parameter * * "VOL=SER= * " has a general JCL * * syntax error. All after VOL=SER is * * treated as JCL comment. * * --------------------------------------- * * More ... * * If the length of the OMPEMSTR parameter * * DATASERVERVOLUME is less than 6, the * * generated JCL is invalid * * "VOL=SER=12345 ,UNIT=SYSDA". * * --------------------------------------- * * More ... * * There is no way to define a DSVOLUME * * and DSUNIT value within OMPEMSTR that * * the corresponding JCL parameter is * * NOT generated. * * --------------------------------------- * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: ---------------------------------------------------------------- PMR 54851 379 000 The OMPEMSTR parameter settings for DATASERVERVOLUME and DATASERVERUNIT are ignored after using PE SERVER operator commands. ---------------------------------------------------------------- PMR 87882 001 866 PE SERVER msg "THE EVENT VSAM DATASET COULD NOT BE CREATED" occurs. The DEFINE CLUSTER parameter VOLUME is not generated. ---------------------------------------------------------------- PMR 03677 499 000 The SMS ACS routine do not accept the DEFINE CLUSTER parameter VOLUME(*) for dataset work-hlq.EVENTS. PE SERVER msg "VSAM dataset creation failed" occurs. ---------------------------------------------------------------- PMR 66216 035 724 The generated PWH bind job PMDBBIND fails, because the JCL parameters UNIT and VOLUME=SER are commented out or an invalid JCL card "VOLUME=SER= * ,UNIT=(SAPPL)" is created. ---------------------------------------------------------------- PMR 48244 379 000 Bind package DBO@CHKB fails if the PE SERVER is started with option PWH=F and option AUTODETECT=Y. ---------------------------------------------------------------- More ... After using the STC modify command DISPLAY=(PARMS) no further dynamic bind of PWH DBRMs is possible, because the JCL parameters VOL=SER and UNIT are commented out. ---------------------------------------------------------------- More ... After using the STC modify command DISPLAY=(PARMS) the VSAM datasets HISTORY and EVENTS are not allocated dynamically in a Non-SMS environment. ---------------------------------------------------------------- More ... For the ICAT specified value blank for DATASERVERVOLUME the OMPEMSTR parameter DATASERVERVOLUME=" * " is created. The resulting JCL parameter "VOL=SER= * " has a general JCL syntax error. All after VOL=SER is treated as JCL comment. ---------------------------------------------------------------- More ... If the length of the OMPEMSTR parameter DATASERVERVOLUME is less than 6, the generated JCL is invalid "VOL=SER=12345 ,UNIT=SYSDA". ---------------------------------------------------------------- More ... There is no way to define a DSVOLUME and DSUNIT value within OMPEMSTR that the corresponding JCL parameter is NOT generated. ---------------------------------------------------------------- PROBLEM CONCLUSION: The default values for UNIT and VOLUME on ICAT panel "KD261PN - Server Information - " are changed to blank. This information is used for PE SERVER work datasets, if not SMS managed. Since SMS can be implemented in different ways, the ICAT configuration tool does not attempt to validate these parameters. The dataset allocation jobs will use all parameters that you enter. A blank value for UNIT results into the OMPEMSTR parameter DATASERVERUNIT='', and the UNIT parameter in the JCL DD statement is not generated. A blank value for VOLUME results into the OMPEMSTR parameter DATASERVERVOLUME='', and the VOL=SER parameter in the JCL DD statement or the VOLUMES parameter in the DEFINE CLUSTER job is not generated. Some PE SERVER work datasets are: - work-hlq.DBRM / PDS - work-hlq.JCL / PDS - work-hlq.EVENTS / VSAM - work-hlq.HISTORY / VSAM - work-hlq.PMDBBIND.JOBSTP / Sequential ---------------------------------------------------------------- KEYWORDS: PESERVER PWH DATASERVERVOLUME DATASERVERUNIT DSVOLUME DSUNIT UNIT VOLUME SMS NONSMS WORK-DATASETS HISTORY EVENTS JCL-PMDBBIND VSAM-VOLUME(*)
Problem conclusion
PROBLEM CONCLUSION: The default values for UNIT and VOLUME on ICAT panel "KD261PN - Server Information - " are changed to blank. This information is used for PE SERVER work datasets, if not SMS managed. Since SMS can be implemented in different ways, the ICAT configuration tool does not attempt to validate these parameters. The dataset allocation jobs will use all parameters that you enter. A blank value for UNIT results into the OMPEMSTR parameter DATASERVERUNIT='', and the UNIT parameter in the JCL DD statement is not generated. A blank value for VOLUME results into the OMPEMSTR parameter DATASERVERVOLUME='', and the VOL=SER parameter in the JCL DD statement or the VOLUMES parameter in the DEFINE CLUSTER job is not generated. Some PE SERVER work datasets are: - work-hlq.DBRM / PDS - work-hlq.JCL / PDS - work-hlq.EVENTS / VSAM - work-hlq.HISTORY / VSAM - work-hlq.PMDBBIND.JOBSTP / Sequential ---------------------------------------------------------------- KEYWORDS: PESERVER PWH DATASERVERVOLUME DATASERVERUNIT DSVOLUME DSUNIT UNIT VOLUME SMS NONSMS WORK-DATASETS HISTORY EVENTS JCL-PMDBBIND VSAM-VOLUME(*)
Temporary fix
Comments
APAR Information
APAR number
PK55453
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2007-10-25
Closed date
2008-04-24
Last modified date
2017-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK35857
Modules/Macros
DGO@BTCH DGO@CONV DGO@LOAD DGO@MIG1 DGO@MIG2 DGO@SCRD DGOVMDSP DGOVMSTR DGOVPP3 DGOZBIND DGOZBTCH DGOZBTC2 DGOZCONV DGOZFL1 DGOZFL2 DGOZLOAD DGOZMIG1 DGOZMIG2 DGOZSCRD FPEUU100 FPEUU311 HKDB410J KDB410J KD2BHELP KD2DDICT KD261CVS KD261HOE KD261HOF KD261HOG KD261PN KD261SB1
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R410 PSY UK35857
UP08/04/28 P F804
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]