A fix is available
APAR status
Closed as program error.
Error description
Abend S0C4 at X'2738' in IOHDCB after abend SD37 for the IOHPDS data set. Also UPDATE FASTGEN SKELETON JCL TO CLARIFY THE USE OF PARENTHESIS FOR THE TARGET= PARAMETER.
Local fix
Give enough disk space to IOHPDS
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Sysgen users. * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C4 in IOHDCB after a D37 for the * * IOHPDS data set. * **************************************************************** * RECOMMENDATION: * **************************************************************** 1. ABEND0C4 in IOHDCB after a D37 for the IOHPDS data set. 2. ABEND0C4 after message IOHC012 is issued for an invalid TRAN EDIT Routine. 3. Update FASTGEN Skeleton JCL to clarify the use of parenthesis for the TARGET= parameter.
Problem conclusion
1. Correct code to locate the DCB that experienced the X37 abend in the DCB ABEND EXIT Routine. 2. Prevent ABEND0C4 after IOHC012 by not deleting module IOHMBLK# until IOHXRMBL ends. 3. Update the Skeleton JCL for the FASTGEN Utility.
Temporary fix
Comments
APAR Information
APAR number
PK51608
Reported component name
IMS HP SYSGEN T
Reported component ID
5655F4300
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2007-08-23
Closed date
2007-09-17
Last modified date
2007-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK29279
Modules/Macros
IOHDCB IOHSFGEN IOHXRMBL
Fix information
Fixed component name
IMS HP SYSGEN T
Fixed component ID
5655F4300
Applicable component levels
R220 PSY UK29279
UP07/09/18 P F709
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89J","label":"IMS HP System Generation Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0"}]
Document Information
Modified date:
22 October 2020