APAR status
Closed as program error.
Error description
Miscellaneous bug fixes.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Fault Analyzer Version 7 users. * **************************************************************** * PROBLEM DESCRIPTION: 01. IDI0120S IBM Fault Analyzer * * internal abend S0C4 at entry point * * prtSynopsis offset X'5974' during * * printing of the Synopsis section of * * the analysis report. * * APAR PK51492 * * 02. Incorrect dump code reported in * * CICS transaction fault analysis * * report. * * APAR PK50166 * * 03. Attempting V line command against a * * fault entry results in "reanalysis * * not possible" message. * * APAR PK50761 * * 04. REXX Notification user exit not * * always executing; IRXEXEC RC=20. * * APAR PK51930 * * 05. Message IDI0047S abend S0C4 at * * entry point usrhdlr_check offset * * X'354'. * * APAR PK51294 * * 06. IMS BMP region hung, waiting for * * ENQ on major name SYSIDIDA minor * * name SYSOUT. * * APAR PK51292 * * 07. Exception in CEEPLPKA after CICS * * startup or after a Fault Analyzer * * NoDup(CICSfast) duplicate. * * APAR PK52009 * * 08. IDI0092S time-out from Fault * * Analyzer with a very large COBOL * * listing. * * APAR PK52367 * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** 01. The success or failure of an internal function call was not being correctly checked. 02. Fault Analyzer was incorrectly determining that an EXEC CICS DUMP request had been issued when invoked in the XDUREQ Global User Exit. 05. Invalid storage was being referenced. 06. An ENQ issued earlier during analysis of an abend in the IEFIIC initiator TCB was still active. 07. A parameter list of 00000000 was being passed on an ATTACH of IDICCFND, which was causing errors during LE initialization. 08. Fault Analyzer processing of a very large COBOL listing for IDILANGX processing from a real time abend can get message IDI0092S because of the extended time required.
Problem conclusion
01. The code has been altered accordingly. 02. Dumps with code AFCI are now reported as transaction dumps instead of EXEC CICS DUMP. 03. The incorrect condition has been fixed to allow a saved report to be viewed correctly. 04. IDIEXEC is now correctly allocated prior to invocation of the REXX Notification user exit. 05. A check has been added to ensure that the storage referenced is valid. 06. Fault Analyzer has been excluded from performing analysis of abends in the IEFIIC initiator TCB. 07. The code has been changed to pass an LE conforming null parameter list instead of 00000000. 08. The call to IDILANGX to process listings for source code analysis, has extended time allowed before loop protection time-out will occur.
Temporary fix
Comments
APAR Information
APAR number
PK49788
Reported component name
FAULT ANALYZER
Reported component ID
5655R4600
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-07-27
Closed date
2007-08-22
Last modified date
2007-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
FAULT ANALYZER
Fixed component ID
5655R4600
Applicable component levels
R710 PSY UK28921
UP07/09/12 P F709
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAJ","label":"Fault Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
02 October 2007