Error description

  • RPT playback engine may leave TCP ports in CLOSE_WAIT state inde
    finitely after failed SSL handshake through a proxy server
    

Local fix

Problem summary

  • An NIO selector in the Java playback engine was not being
    closed in some situations where an error occurred and an
    exception was thrown. This caused the network connection on
    the client side to stay open in the CLOSE_WAIT state and not
    be disposed.
    

Problem conclusion

  • Now, all the error conditions are inside a try-finally
    construct that will close the selector when completed. This
    solves not only this particular problem but many similar
    ones for different errors.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK49512

  • Reported component name

    PERF TESTER 6.1

  • Reported component ID

    5724J9601

  • Reported release

    700

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-07-23

  • Closed date

    2007-10-16

  • Last modified date

    2007-10-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    PERF TESTER 6.1

  • Fixed component ID

    5724J9601

Applicable component levels

  • R700 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSMMM5","label":"IBM Rational Performance Tester"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
16 October 2007