A fix is available
APAR status
Closed as program error.
Error description
ABEND822 IN APPC INITIATOR DUE TO LSQA FRAGMENTATION CAUSED BY RACF ACEE CONTROL BLOCKS NOT BEING FREED. Additional Kewords: Abends822 s822 822
Local fix
no work around
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Sysgen users. * **************************************************************** * PROBLEM DESCRIPTION: Abend822 in APPC Initiator. * **************************************************************** * RECOMMENDATION: * **************************************************************** ABEND822 in APPC Initiator due to LSQA fragmentation caused by RACF ACEE control blocks.
Problem conclusion
Correct HP Sysgen cleanup processing to ensure that ACEE control blocks are deleted when processing is complete.
Temporary fix
Comments
APAR Information
APAR number
PK46826
Reported component name
IMS HP SYSGEN T
Reported component ID
5655F4300
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2007-06-11
Closed date
2007-08-23
Last modified date
2007-09-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK28511 UK28512
Modules/Macros
IOHZRACF
Fix information
Fixed component name
IMS HP SYSGEN T
Fixed component ID
5655F4300
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89J","label":"IMS HP System Generation Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"210"}]
Document Information
Modified date:
14 December 2020