PK46793: PRF ABEND0C4 IN AN ERROR MESSAGE ROUTINE AFTER A DYNAMIC ALLOCATION FAILURE FOR THE CTDS TRACKING DATA SET.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Abend S0C4 ( abends0c4 ) at offset x'83E' in Csect IRTXSC00,
    eyecatcher 20051203-04.23-2.1.0.910-PK09539 H23D210 - V2R1M0
    5655-E14.  This occurs after dynamic allocation fails for the
    CTDS (Checkpoint ID Tracking Data Set).
    

Local fix

  • No work around.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IMS Program Restart Facility.   *
    ****************************************************************
    * PROBLEM DESCRIPTION: Program Restart is abending ABENDS0C4   *
    *                      in an error message routine after a     *
    *                      dynamic allocation for a CTDS tracking  *
    *                      data set.                               *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Program Restart should terminate the job with a U3620 abend
    code if there is a dynamic allocation failure for a CTDS
    tracking data set. Instead a S0C4 abend occurs in a message
    rooutine.
    

Problem conclusion

  • Program Restart has been corrected to display the appropriate
    error message before abending U3620.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK46793

  • Reported component name

    IMS PGM RESTART

  • Reported component ID

    5655E1400

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2007-06-08

  • Closed date

    2007-06-12

  • Last modified date

    2007-07-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK26025

Modules/Macros

  •    IRTXSC05 IRTXSC06 IRTXSC07 IRTXSC08 IRTXSC09
    IRTXSC10
    

Fix information

  • Fixed component name

    IMS PGM RESTART

  • Fixed component ID

    5655E1400

Applicable component levels

  • R210 PSY UK26025

       UP07/06/13 P F706