IBM Support

PK44696: ABEND337 RC04 IF IOHPDS DATA SET NAME SPECIFIED     ON MAIN MENU IS A SEQUENTIAL FILE.    &#1

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • High Performance Sysgen gets an abend Abend S337-04
    when processing command 'IOHXEDIT' selecting the EDIT
    function.  Similar problems for VERIFY and INSTALL in panel
    IOH@PRIM.  This happens only if the data set specified isn't a
    PDS.
    Code will be changed to verify that the data set is a PDS before
    reading the directory.
    

Local fix

  • Specify a PDS as the data set.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Sysgen V2R2 users.  *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND337 if IOHPDS data set name        *
    *                      specified on main menu is a             *
    *                      sequential file.                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    ABEND337 if IOHPDS data set name specified on main menu is a
    sequential file.
    Correct error message numbers issued by IOHBRVRS.
    Terminal security updates and undo list entries are not saved
    correctly in the IOHPDS.
    Message IOH4402E possible when installing an update list with
    an update CTRANS entry.
    

Problem conclusion

  • Verify that IOHPDS is a PDS before reading directory
    Correct 2 error message numbers issued by Batch Reverse utility.
    Correct error that may cause some Resource Update lists
    not to be saved.
    

Temporary fix

Comments

  • ×**** PE07/08/17 PTF IN ERROR. SEE APAR PK51232  FOR DESCRIPTION
    

APAR Information

  • APAR number

    PK44696

  • Reported component name

    IMS HP SYSGEN T

  • Reported component ID

    5655F4300

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2007-05-07

  • Closed date

    2007-05-30

  • Last modified date

    2007-08-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK25654

Modules/Macros

  • IOHBRVRS IOHDCB   IOHXEMBR IOHXLOG4 IOHXPDS
    IOHXPDS2 IOHXVIEW IOHZCHK0 IOHZCHK7 IOHZCHK8 IOHZCHK9 IOHZMTX7
    IOHZMTX8 IOHZMTX9
    

Fix information

  • Fixed component name

    IMS HP SYSGEN T

  • Fixed component ID

    5655F4300

Applicable component levels

  • R220 PSY UK25654

       UP07/05/31 P F705

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89J","label":"IMS HP System Generation Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0"}]

Document Information

Modified date:
22 October 2020