Error description

  • NEW FUNCTION PTF. INFO TO BE ADDED.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   Tivoli Enterprise Monitoring Agent       *
    *                 -   ICAT                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. The High-Level qualifier for data    *
    *                      sets of the OMEGAMON Server             *
    *                      can have a maximum length of 15         *
    *                      characters only.                        *
    *                      2. Data Server auto detection of DB2    *
    *                      subsystems is enabled by default, but   *
    *                      cannot be switched off.                 *
    *                      3. Only up to 14 DB2 subsystems can be  *
    *                      monitored                               *
    *                      4. For the steps in 'Complete the       *
    *                      configuration' it is not always         *
    *                      clear which are mandatory and which     *
    *                      have to be performed only under certain *
    *                      circumstances. Moreover it is not clear *
    *                      which privileges are necessary to       *
    *                      perform a certain step.                 *
    *                      5. Tivoli Enterprise Monitoring Agent   *
    *                      (TEMA) for DB2 starts internal subtasks *
    *                      that are not necessary any more.        *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    1. The High-Level qualifier for data sets of the OMEGAMON Server
    can have a maximum length of 15 characters only.
    2. Data Server auto detection of DB2 subsystems is enabled by
    default, but cannot be switched off.
    3. Only up to 14 DB2 subsystems can be monitored.
    4. The steps in 'Complete the configuration' need to be enhanced
    to make completing the configuration easier.
    5. Abend ABEND80A-10 caused by excessive resource consumption.
    

Problem conclusion

Temporary fix

Comments

  • 1. The maximum length of the High-Level qualifier for data sets
    of the OMEGAMON Server is increased from 15 to 18 characters.
    
    2. The AUTODETECT parameter is externalized. This option lets
    you activate and deactivate the Data Server auto detection of
    active DB2 subsystems that are not explicitly configured during
    the configuration process. If you specify Y the automatic start
    up of the monitoring for all active DB2 subsystems in the LPAR
    are enabled.
    
    3. The number of DB2 subsystems that can be monitored is
    increased from 14 to 32.
    
    4. The steps in 'Complete the configuration' are grouped in
    categories mandatory, if applicable and optional steps. A common
    structure for all 'Complete the configuration steps was
    introduced consisting of the following sections:
    * Objective: why do you have to perform this step
    * Requirements (only for If applicable steps): under which
    circumstances do you have to perform this step.
    * Requ. authorization: which privileges are necessary to perform
                           the step
    * Description: what has to be done
    The parameters and job names that are referenced in 'Complete
    the configuration' are always expanded with the values
    specified during the configuration process.
    
    5. Only necessary subtasks for DB2 TEMA are started.
    
    KEYWORDS : COMPLETE THE CONFIGURATION AUTODETECT DATASERVER
    DATASETS HLQ MAXIMUM NUMBER SUBSYSTEMS DB2-TEMA
    ABEND80A-10
    ×**** PE08/06/12 FIX IN ERROR. SEE APAR PK62337  FOR DESCRIPTION
    

APAR Information

  • APAR number

    PK43337

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2007-04-16

  • Closed date

    2007-07-09

  • Last modified date

    2017-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK26887

Modules/Macros

  •    DGONFPAC DGONF023 DGONF070 DGONF170 DGONSLCK
    DGOVCRDB DGOVFTAB DGOVFTIN DGOVRA   DGOVSCLO DGOVSCNI DGOVSCNT
    DGOVSFLR DGOVSGFT DGOVSLOC DGOVSORT DGOVSQFM DGOVSTQL DGOVS700
    DGOVUDAT DGOVUFTL KDBZC03  KDBZC04  KDPIMSG0 KDPIMSH0 KDPIMSI0
    KDPIMSJ0 KDPIRLCP KDPIRLCQ KDPIRLDP KDPLOKC0 KDPLOKD0 KD2BHELP
    KD2DDICT KD2SBATO KD261CB1 KD261CB2 KD261CCU KD261COS KD261DFI
    KD261HO  KD261HOA KD261HOB KD261HOC KD261HOD KD261HOE KD261HOF
    KD261HOG KD261OS  KD261PN  KD261P2  KD261SEX KD261SJ4 KD261SO2
    KD261SO3 KD261SO4 KD261SPW KD261SS3 KD2610R1 KD2610SP KD5AGENT
    KD5CICFP KD5CICFQ KD5CICGP KD5CICGQ KD5CICHP KD5CICHQ KD5CICIP
    KD5CICIQ KD5CMD00 KD5COL00 KD5GBPFP KD5GBPFQ KD5GBPGP KD5GBPGQ
    KD5GBPHP KD5GBPHQ KD5GBPIP KD5GBPIQ KD5GOA00 KD5GOB00 KD5GOV00
    KD5SCMF0 KD5SCMG0 KD5SCMH0 KD5SCMI0 KD5SUBFP KD5SUBFQ KD5SUBGP
    KD5SUBGQ KD5SUBHP KD5SUBHQ KD5SUBIP KD5SUBIQ KD5SUCFP KD5SUCFQ
    KD5SUCGP KD5SUCGQ KD5SUCHP KD5SUCHQ KD5SUCIP KD5SUCIQ KD5THDFP
    KD5THDFQ KD5THDGP KD5THDGQ KD5THDHP KD5THDHQ KD5THDIP KD5THDIQ
    KO2APCAA KO2APCAS KO2APCA2 KO2APCCA KO2APCCS KO2APCC2 KO2APC1A
    KO2APC1S KO2APC12 KO2APC2A KO2APC2S KO2APC22 KO2APC3A KO2APC3S
    KO2APC32 KO2APC4A KO2APC4S KO2APC42 KO2APC9A KO2APC9S KO2APC92
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R410 PSY UK26887

       UP07/07/12 P F707

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
04 February 2017