A fix is available
APAR status
Closed as program error.
Error description
A system abend 0C4 PIC 11 occurred in DSQFQDRM or DSQDUPNM after the APPLY of PK34089(UK19727,UK19728,UK19729,UK19730) when printing a FORM that contains a user-defined column. A "DSQ60300 FM error -Invalid source data type *** CMD=PRINT" can also occur. abends0c4 s0c4 abend0c4 rc11
Local fix
Remove PK34089/(UK19727,UK19728,UK19729,UK19730)
Problem summary
**************************************************************** * USERS AFFECTED: All QMF for TSO/CICS V7.1, V7.2, V8.1, and * * V9.1 users * **************************************************************** * PROBLEM DESCRIPTION: If PK34089/UK19729 are applied, * * unpredictable errors can occur when * * report results are printed using * * a FORM that contains a user-defined * * column. Errors seen include an * * ABENDS0C4 in DSQFQDRM or DSQDUPNM and * * the error message * * "DSQ60300 FM error - Invalid source * * data type. *** CMD=PRINT". Any error * * from PRINT REPORT using a FORM is a * * possible candidate for this fix. * **************************************************************** * RECOMMENDATION: * **************************************************************** The fix for PK34089 reinitialized some report flags to zero at the beginning of new-report processing in DSQFPREF. However, this code is executed twice for a single report if that report is printed. Flags that were set when the report was first generated need to be still extant when that report is printed, or, for certain form configurations, error conditions can occur.
Problem conclusion
The code that reinitializes form flags was removed from DSQFPREF.
Temporary fix
Comments
APAR Information
APAR number
PK39338
Reported component name
QMF-QUERY MGMT
Reported component ID
566872101
Reported release
810
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-02-13
Closed date
2007-02-16
Last modified date
2007-03-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK22287 UK22288 UK22289 UK22290
Modules/Macros
DSQFPREF
Fix information
Fixed component name
QMF-QUERY MGMT
Fixed component ID
566872101
Applicable component levels
R710 PSY UK22287
UP07/02/23 P F702
R720 PSY UK22288
UP07/02/23 P F702
R810 PSY UK22289
UP07/02/23 P F702
R910 PSY UK22290
UP07/02/23 P F702
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCWRCK","label":"QMF for TSO\/CICS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: