IBM Support

PK37136: CQM2002E MESSAGE MAY BE ISSUED AFTER AN S878-10 ABEND OCCURS IN THE QM ADDRESS SPACE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • CQM2002E message may be issued after an S878-10 abend occurs in
    the QM address space
    
    OTHER KEYWORDS: ABENDS878 ABEND878 S878 878 CQM2002
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Query Monitor.                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: CQM2002E message may be issued after an *
    *                      S878-10 abend occurs in the QM address  *
    *                      space.                                  *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK37136

  • Reported component name

    DB2 QUERY MONIT

  • Reported component ID

    5655E6701

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2007-01-09

  • Closed date

    2007-03-02

  • Last modified date

    2007-04-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK22655 UK22656

Modules/Macros

  •    CQM#COMM CQM#DRVR CQM#INIT CQM#MSTB CQM#RESM
    CQM#REST CQM#SSMN CQMMINST CQMOINST
    

Fix information

  • Fixed component name

    DB2 QUERY MONIT

  • Fixed component ID

    5655E6701

Applicable component levels

  • R220 PSY UK22655

       UP07/03/09 P F703

  • R221 PSY UK22656

       UP07/03/09 P F703

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220"}]

Document Information

Modified date: