Error description

  • HPIC terminates with ABEND U4000 RSN=13 and message FABJ4613E
    when command /STA fails - even when FASTIC=COPY and AOIAUTO=N .
    are used. HPIC reads an incorrect field in control blocks and
    the 5th character of DDN is regarded as TOIAUTO control.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 4 Release 1 users ( FMID=H1J0410 )   *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR fixes following problems:     *
    *                      - HPIC Image Copy function terminates   *
    *                        with ABEND U4000 ( ABENDU4000 ) and   *
    *                        message FABJ4613E ( MSGFABJ4613E ),   *
    *                        when FASTIC=(,DUMP) or FASTIC=(,COPY) *
    *                        is specified in ICEIN and the 5th     *
    *                        character of DDN of the input DBDS is *
    *                        'Y'.                                  *
    *                      - HPIC Image Copy function terminates   *
    *                        with ABEND U0047 ( ABENDU0047 ) and   *
    *                        message DFS047A ( MSGDFS047A ) when   *
    *                        following conditions are fulfilled.   *
    *                         - FASTIC=COPY process                *
    *                         - Batch Image Copy                   *
    *                         - WAIT contorol is requested         *
    *                           (explicitly or implicitly) during  *
    *                           process of DSGs                    *
    *                      - HPIC Recovery function may terminate  *
    *                        abnormally when an image copy data    *
    *                        set generated by FASTIC=COPY process  *
    *                        is specified as input data set in     *
    *                        an IMS-compatible JCL.                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    This APAR fixes following problems:
    - HPIC Image Copy function, terminates with ABEND U4000
      ( ABENDU4000 ) and message FABJ4613E ( MSGFABJ4613E ), when
      FASTIC=(,DUMP) or FASTIC=(,COPY) is specified in ICEIN and the
      5th character of DDN of the input DBDS is 'Y'.
      Because HPIC refers to an invalid field in control blocks and
      regards 5th character of DDN as a value of TOIAUTO= parameter.
    - HPIC Image Copy function terminates with ABEND U0047
      ( ABENDU0047 ) and message DFS047A ( MSGDFS047A ) when
      following conditions are fulfilled.
       - FASTIC=COPY process
       - Batch Image Copy
       - WAIT contorol is requested (explicitly or implicitly)
         during process of DSGs
      Because HPIC does not set address of IMS control block for
      DBRC unauthorization process and the process has failed.
    - HPIC Recovery function may terminate abnormally when an image
      copy data set generated by FASTIC=COPY process is specified as
      input data set in an IMS-compatible JCL.
      Because HPIC attempts to refer to a control block which is not
      generated in the process.
      HPIC should end the process with RC=8 and issue message
      DFS312A ( MSGDFS312A ).
    

Problem conclusion

  • FABJDFCN has been modified to change timing of issuing FREEMAIN
    macro for internal work area.
    
    FABJDMPN has been modified as follows:
    - To create the HPIC control block by the every part of HALDB,
      when FASTIC=(,DUMP) or FASTIC=(,COPY) is specified in the
      ICEIN and processed database is HALDB.
    - To pass an address of IMS control block used by DBRC
      unauthorization process to FABJDFCN.
    
    FABJFCCN and FABJFCDN have been modified to search the HPIC
    control block with the part name of HALDB, when processed
    database is HALDB.
    
    FABJRDB7, FABJRDB8, and FABJRDB9 have been modified to check
    whether the process has started by IMS-compatible JCL or not,
    and to terminate with RC=8 and message DFS312A if the process
    has started by IMS-compatible JCL.
    
    FABJSTA has been modified to receive correct address of HPIC
    control block.
    
    The following modules have been reassembled:
    FABJDFC7, FABJDFC8, FABJDFC9, FABJFCC7, FABJFCC8, FABJFCC9
    FABJDMP7, FABJDMP8, FABJDMP9, FABJFCD7, FABJFCD8, FABJFCD9
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK29015

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2006-07-31

  • Closed date

    2006-08-07

  • Last modified date

    2006-09-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK17013

Modules/Macros

  • FABJDFCN FABJDFC7 FABJDFC8 FABJDFC9 FABJDMPN
    FABJDMP7 FABJDMP8 FABJDMP9 FABJFCCN FABJFCC7 FABJFCC8 FABJFCC9
    FABJFCDN FABJFCD7 FABJFCD8 FABJFCD9 FABJRDB7 FABJRDB8 FABJRDB9
    FABJSTA
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R410 PSY UK17013

       UP06/08/09 P F608

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"4.1.0","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 December 2020