PK27060: ADD MORE THRESHOLD OPTIONS ON SPACE MONITOR JCL

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • This APAR will add more threshold options for Space Monitor JCL
    generated by Database Control Suite.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: DATABASE CONTROL SUITE V3R2                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR fulfills requirements         *
    *                      MR050205239 and MR0502051719 to add     *
    *                      more options to Monitor database        *
    *                      support.                                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    MR050205239 - Adds all the threshold criteria available under
     Space Monitor SPMNMBR to the Control Suite Monitor Database
     subtask. The full two line control statement is now included
     in the Space Monitor JCL generated by Control Suite.
    MR0502051719 - Adds the ability to browse the Space Monitor
     Messages and Exception Report, as well as the Space Monitor
     Analysis Reports for monitored databases.
    

Problem conclusion

Temporary fix

Comments

  • If you have previously run the Space Monitor Setup and
    Report tasks in Database Control Suite, you should run a
    task to reinitialize DBDSGRP table fields that involve the
    Space Monitor options for the affected CSIDs.
    If the field options are not reinitialized, unexpected
    errors may occur in Monitor Setup and other Monitor subtasks.
    To run the initialization task -
     1. Install the PTF.
     2. Start Control Suite as usual and select a CSID.
     3. Select task 6 - SYSTEM ADMINISTRATION - on panel IDLP00.
     4. Select subtask 4 - Update table data set after SMPE
        Maintenance - on panel IDLPA0.
     5. All the affected fields in the CSID DBDSGRPS will be
        initialized to blanks.
     6. You may then select and run Monitor Setup.
    

APAR Information

  • APAR number

    PK27060

  • Reported component name

    IMS DB CNTL SUI

  • Reported component ID

    5655F7600

  • Reported release

    320

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-06-23

  • Closed date

    2006-06-29

  • Last modified date

    2006-08-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK15889

Modules/Macros

  • IDLCA0   IDLC0001 IDLC31   IDLC33   IDLH0780
    IDLH0782 IDLH0784 IDLH0790 IDLH0920 IDLH0930 IDLH0932 IDLH0934
    IDLH0940 IDLH0942 IDLH0944 IDLH1000 IDLH1010 IDLI00   IDLMCRIT
    IDLMXDS1 IDLMXDS2 IDLP31P  IDLP31X  IDLSMUJB IDLUPDJL
    

Fix information

  • Fixed component name

    IMS DB CNTL SUI

  • Fixed component ID

    5655F7600

Applicable component levels

  • R320 PSY UK15889

       UP06/07/05 P F607

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88W","label":"IMS Database Control Suite"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0"}]

Document Information

Modified date:
22 October 2020