Error description

  • Currently rows with TIME columns containing seconds cannot be
    updated if the subsystem default is TIME=USA.  This enhancement
    allows editing under these conditions:
     - non-time columns can now be updated/deleted
     - time value columns that contain 0 seconds or null values can
       now be updated/deleted
    .
    Attempts to edit a time value containing seconds will not be
    allowed.  The new message, MSGETI088E :
     ETI088E- Time column contains seconds and can not be updated
    will be displayed in these cases.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Table Editor.                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: Currently rows with TIME columns        *
    *                      containing seconds cannot be updated    *
    *                      if the subsystem default is TIME=USA.   *
    *                      This enhancement allows editing under   *
    *                      these conditions:                       *
    *                       - non-time columns can now be          *
    *                         updated/deleted                      *
    *                       - time value columns that contain 0    *
    *                         seconds or null values can           *
    *                         now be updated/deleted               *
    *                      Attempts to edit a time value           *
    *                      containing seconds will not be allowed. *
    *                      The new message, MSGETI088E :           *
    *                      ETI088E- Time column contains seconds   *
    *                      and can not be updated                  *
    *                      will be displayed in these cases.       *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

Temporary fix

Comments

  • APPLY the PTF.
    

APAR Information

  • APAR number

    PK20816

  • Reported component name

    DB2 TABLE EDITO

  • Reported component ID

    5697G6500

  • Reported release

    130

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-03-02

  • Closed date

    2006-03-09

  • Last modified date

    2006-04-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK12462

Modules/Macros

  •    ETI$ADMN ETI$ADM1 ETI$BLOC ETI$BULD ETI$COLS
    ETI$COMM ETI$DELL ETI$DPSC ETI$DPTB ETI$DSQL ETI$EDIT ETI$EXPL
    ETI$FORM ETI$INDX ETI$LOAD ETI$MAIN ETI$PARS ETI$SAVE ETI$STGM
    ETI$UPDT ETI@CONN ETI@IOCT ETI@IOID ETI@IOSC ETI@IOTB ETI@PREP
    ETI@TCHK ETI@VALD ETI@WDUP ETI@WRIT ETIALLZT ETICAPST ETICHART
    ETIHEXE1 ETIHEXE2 ETIHEXE3 ETINBLKT ETINNUMT ETINPRNT ETIPRNTT
    ETI08    ETI13
    

Fix information

  • Fixed component name

    DB2 TABLE EDITO

  • Fixed component ID

    5697G6500

Applicable component levels

  • R130 PSY UK12462

       UP06/03/11 P F603

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCVQU2","label":"Db2 Table Editor"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.3.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
05 April 2006