Error description
Message DSQ20847 is issued from QBE when names greater than 9 characters long are entered in the SAVE Command Prompt panel that is generated by the SAVE QUERY ? command.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All QMF for TSO and CICS V81 QBE users. * **************************************************************** * PROBLEM DESCRIPTION: Message DSQ20847, "SAVE QBE QUERY needs * * a valid name", is issued if users try * * to save a QBE query via the SAVE * * Command Prompt panel, and the NAME * * portion of LOC.NAME is greater than 9 * * characters. * **************************************************************** * RECOMMENDATION: * **************************************************************** QMF SAVE logic assigns a value that is double the length of the NAME value supplied by users in the SAVE Command Prompt panel. Since long name support is not available in QBE, 18 bytes is the maximum name length allowed. Thus, a 9 byte name, whose length was doubled to 18 bytes, was the longest name allowed for QBE SAVE QUERY processing.
Problem conclusion
QBE SAVE logic has been amended to not assign a doubled length value for QBE NAMES.
Temporary fix
Comments
APAR Information
APAR number
PK19989
Reported component name
QMF-QUERY MGMT
Reported component ID
566872101
Reported release
810
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-02-16
Closed date
2006-02-22
Last modified date
2006-04-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK12018
Modules/Macros
DSQDSAVE
Fix information
Fixed component name
QMF-QUERY MGMT
Fixed component ID
566872101
Applicable component levels
R810 PSY UK12018
UP06/03/09 P F603
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCWRCK","label":"QMF for TSO\/CICS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: